The LED display will only show that a PA module has faulted. The specific fault condition is indicated on the
T-4180 Module Status screen #2.
When the fault condition disappears, the faul
t LED’s will turn OFF on the next key – or in case of a critical
fault
– the power has been turned OFF and ON again.
Power Supply Module:
The 50VDC supply voltage is monitored by the microprocessor in the System Controller module. A power
supply fault is declared whenever the supply voltage falls outside the voltage range of 45V to 53V.
Transmitter keying is inhibited if the supply voltage is above 53V in the Power Supply module.
With a fault in the 50VDC power supply, the System Controller and PA module LED display is as
shown below.
Power
Supply
Module
Fault
1.25kW PA
Module LED’s
System Controller FAULT LED’s
PWR
FAULT
TEMP
VSWR
SPLY
AIR
FLOW
Exceeding
limits
OFF
OFF
OFF
OFF
ON
OFF
When the fault condition disappears, the fault display is cleared on the next key.
Note: The Power Supply module will start current limiting at approximately 325A and enter
“constant current mode” of operation. Excessive current draw does not necessarily indicate
a failure of the 50VDC supply but may be caused by the operating conditions that affect the
efficiency of the Transmitter.
Combiner Module:
a.
A fan fault is declared if, when keyed, the fan current is above or below specific hardware set limits.
b.
A temperature (TEMP) fault is declared when the Combiner module heatsink temperature exceeds
approximately 100°C.
With a fault in the Combiner module, the System Controller and PA module LED display is as shown below.
Combiner
Module
Fault
1.25kW PA
Module LED’s
System Controller FAULT LED’s
PWR
FAULT
TEMP
VSWR
SPLY
AIR
FLOW
FAN
ON
OFF
OFF
OFF
OFF
ON
TEMP
ON
OFF
ON
OFF
OFF
OFF
Содержание COM5000-8
Страница 6: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL iv FRONT VIEW OF TRANSMITTER ...
Страница 22: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL 12 Figure 3 2 1 Power Supply Module Front Panel ...
Страница 24: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL 14 Figure 3 2 2 PA Module Front Panel ...
Страница 25: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL 15 Figure 3 2 3 System Controller Module Front Panel ...
Страница 43: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL 33 Figure 5 4 1A 1 25kW PA Module Subassembly Location ...
Страница 63: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL 53 Figure 5 1 Transmitter Interconnect Wiring Diagram ...
Страница 64: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL 54 Figure 5 4 1 PA Module Interconnect Wiring Diagram ...
Страница 65: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL 55 Figure 5 4 3 System Controller Interconnect Wiring Diagram ...
Страница 66: ...351804 1 Rev 100 COM5000 8 TECHNICAL MANUAL 56 Figure 5 4 4 Power Supply Interconnect Wiring Diagram ...