background image

11

GG-H2S

Limited Warranty & Limitation of Liability

Calibration Technologies, Inc. (CTI) warrants this product to be free from defects in material and workmanship 

under normal use and service for a period of two years (including the cell), beginning on the date of shipment 

to the buyer. This warranty extends only to the sale of new and unused products to the original buyer. CTI's 

warranty obligation is limited, at CTI's option, to refund of the purchase price, repair, or replacement of a 

defective product that is returned to a CTI authorized service center within the warranty period. In no event shall 

CTI's liability hereunder exceed the purchase price actually paid by the buyer for the product.

This warranty does not include:
a)  routine replacement of parts due to the normal wear and tear of the product arising from use;

b)  any product which in CTI's opinion, has been misused, altered, neglected or damaged by accident or abnormal 

conditions of operation, handling or use;

c) any damage or defects attributable to repair of the product by and person other than an authorized dealer or 

contractor, or the installation of unapproved parts on the product

The obligations set forth in this warranty are conditional on:
a) proper storage, installation, calibration, use, maintenance and compliance with the product manual 

instructions and any other applicable recommendations of CTI;

b) the buyer promptly notifying CTI of any defect and, if required, promptly making the product available for 

correction. No goods shall be returned to CTI until receipt by the buyer of shipping instructions from CTI; and

c) the right of CTI to require that the buyer provide proof of purchase such as the original invoice, bill of sale or 

packing slip to establish that the product is within the warranty period.

THE BUYER AGREES THAT THIS WARRANTY IS THE BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF 

ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY 

OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. CTI SHALL NOT BE LIABLE FOR ANY SPECIAL, 

INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER 

ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT OR RELIANCE OR ANY OTHER THEORY.

Содержание GG-H2S

Страница 1: ...Installation and Operation Manual GG H2S HYDROGEN SULFIDE GAS SENSOR...

Страница 2: ...ly in the manner described in this manual If the equipment is used in a manner not specified by Calibration Technologies the protection provided by the equipment may be impaired This equipment should...

Страница 3: ...es 920 N Tradewinds Pkwy Columbia MO 65201 866 394 5861 sales ctiengineering com www ctiengineering com General description 4 Installation 4 Locating the sensor 4 Installation guidelines 5 Wiring 6 Op...

Страница 4: ...oisture variations that occur during daily process cycles The transmitter circuit board is sealed in potting compound protecting sensitive electronic components and copper tracing from corrosion The s...

Страница 5: ...om mercury vapor lights variable speed drives and radio repeaters Protect sensor from physical damage forklifts etc If mounting on a wall with studs the mounting screws should be screwed into the stud...

Страница 6: ...scale range Wiring Guidelines Always use 3 conductor insulate stranded shielded copper cable Do not pull sensor wiring with AC power cables This can cause electrical interference If cable runs cannot...

Страница 7: ...in mA Always use mVDC or VDC voltmeter settings Zero Calibration After the unit is installed and has been powered up for a minimum of 12 hours the unit can be zero calibrated by the following Be sure...

Страница 8: ...ed Fault red LED On steady if supply voltage is less than 10VDC Status amber LED Blinks once per second if RFI is detected Power green LED On steady to Indicate Power Blinks once per second for 60 sec...

Страница 9: ...installed in the same room All tests and calibrations must be logged Always disconnect power at the controller before performing any wiring at the sensor Sensor Life These electrochemical cells are ex...

Страница 10: ...Linearity 0 5 of full scale Repeatability 1 of full scale Temperature Range 0 F to 120 F 18 C to 49 C Humidity Range 5 to 100 condensing Dimensions 7 7 high x 6 7 wide x 3 8 deep Weight 3 lbs Wiring C...

Страница 11: ...f the product by and person other than an authorized dealer or contractor or the installation of unapproved parts on the product The obligations set forth in this warranty are conditional on a proper...

Страница 12: ...ctiengineering com 866 394 5861 GG H2S DOC1 0 20190605...