-6-
Vision Gage Diagram
Electrical Installation:
The CTD D45’s use two 2 H.P. single or three phase 3450 RPM, 60 HZ TEFC (totally enclosed fan cooled)
motors on a NEMA 56Z Frame. CTD uses a speed up drive so that the blade will run at approximately 3700 RPM.
Electrical installation should be performed by a qualified and certified electrician. A lock-out or disconnect switch
is located in front of the machine. It is a rotary switch to the left front of the machines. This disconnect switch is
used to shut off power to the machine and should be used whenever the blades are changed or at any time the
machine is serviced and the blades are exposed. A Dual Magnetic Starter, located inside the left side panel of the
machine protects the motor from overheating and will not allow the motor to restart itself after power outages or
undervoltage situations. The START button turns the motors “ON”. The STOP button turns the motor “OFF”.
Note: The STOP button must be pulled out before the START button will activate the motors.
I
f the blade guard is not set in place properly, the motors will not turn on. An interlock switch located below the
blade guard must be contacted before power is supplied to the starter.
Electrical Installation of Power to Starter by a Qualified Electrician:
All wiring from the motors to the starter has been completed and tested at the factory several times. The voltage
has been clearly tagged.
DO NOT CONNECT ANY VOLTAGE THAT IS DIFFERENT THAN THE TAGGED
VOLTAGE, AS THIS MAY CAUSE SEVERE DAMAGE AND DANGER.. CONSULT FACTORY IF ANY
CHANGES ARE NEEDED.
Bring incoming power lines to the rear of the machine on left side using hard wire and dust proof connectors.
Attach incoming power lines through Floor Stand to the rotary disconnect switch. Connect to terminals 2 & 4
for single phase motors, and to terminals 2,4 & 6 for three phase motors. Always ground the green wire.
(See wiring diagram on Page 7.)
Single Phase Motor Replacement:
Connect motor leads to T1 and T3 of overload relay for single phase motors. (See wiring diagram for single
phase motors on following page) Green ground wire must be grounded to enclosure. If using type “SO” wire
and plug, use a dust tight connector through Floor Stand and a grounded plug.
Be sure to check
rotation. If a
change is necessary, open the motor box located on the motor, and switch the #8 and the #5 wires. This reverses
the rotation of a single phase motor. The blade must rotate down and to the rear on the underside of the blade
(see Diagram “D” on Page No. 8).
Содержание D45AX
Страница 20: ...20 D45AX D45FX SAW HEAD ASSEMBLIES...
Страница 21: ...21 D45AX D45FX SAW HEAD ASSEMBLY PARTS LIST...
Страница 22: ...D45AX BASE AND AIR SYSTEM ASSEMBLY 22...
Страница 23: ...D45AX BLADE GUARD AND STAND ASSEMBLY 23...
Страница 24: ...New Style D45AX Pivot Assy Used After March 2007 25...
Страница 25: ...Air Stop Exploded View D45 Chip Breaker Exploded View 27...