MNX10030  Rev 0 

          

                             

8/20/2008  

1

 

 
 
Section I 
Overview 

Introduction.....................................................................….… 2 
Description.............................................................................. 2 
 

Section II 
Installation 

Mounting………....................................................................... 4 
Electrical Connections............................................................. 5 

 

Section III 
Operation 

Operating Procedure............................................................... 6 

 

Section IV 
Maintenance 

General.................................................................................... 8 
Warranty.................................................................................. 8 

 

Figures 

Figure 1 (Selection Guide)……………………...………………...3 
Figure 2 (Mounting Bracket Location)...................................... 4 
Figure 3 (Conduit Entry Layout).……………….……………..… 4 
Figure 4 (Grounding Enclosure)………………...…………….….5 
Figure 5 (Enclosure Wiring Locations)…………………………..6 
 

Table 

Table 1 (Specifications)………………………..………….….…. 3 

 
 
 
 
 
 
 
 
 
 
 
 

Contents 

Содержание XE150

Страница 1: ...Product Manual MNX10030 REV 0 MODEL XE150 Enclosure for SC200 Series Premium Signal Conditioners ...

Страница 2: ...cal Connections 5 Section III Operation Operating Procedure 6 Section IV Maintenance General 8 Warranty 8 Figures Figure 1 Selection Guide 3 Figure 2 Mounting Bracket Location 4 Figure 3 Conduit Entry Layout 4 Figure 4 Grounding Enclosure 5 Figure 5 Enclosure Wiring Locations 6 Table Table 1 Specifications 3 Contents ...

Страница 3: ...oth a 0 10 VDC output and a 4 20mA output and a temperature output in 0 1 2 VDC and sensor input vibration displacement and temperature inputs these connections are based upon the XE150 variant ordered There is also a green indicator light Transducer Signal OK which illuminates when the sensor is properly connected to the transmitter and working correctly The power supply accepts input voltage of ...

Страница 4: ... to the specified full scale output Performs a true RMS conversion if needed and transmits this data into specified output ENCLOSURE DIMENSIONS Small Enclosure 1 6 Channels 12 x 10 x 6 Large Enclosure 6 12 Channels 16 x 14 x 8 TEMPERATURE RATING OF ENCLOSURE 50 degrees F to 180 degrees F ENCLOSURE RATING NEMA 4X Table 1 Specifications Specifications on a particular Signal Conditioner may be obtain...

Страница 5: ...ends the conduit cable entry from the bottom of the enclosure when mounted NOTE To ensure moisture will not flow into the enclosure a hole should be drilled at the lowest point in the conduit to provide drainage for any moisture Section II Installation Figure 2 Mounting Bracket Location Mounting Brackets CTC Vibration Enclosure Cable Input From Sensors Cable Outputs Power Cable Input Figure 3 Cond...

Страница 6: ...e right side of the enclosure as indicated by the labeling Sensor Input NOTE If there is no sensor wired to the sensor input terminal the corresponding transmitter for that channel will not power on Be sure to power the system on AFTER the sensor has been connected NOTE If utilizing cord grips ensure that all cord grips are used Empty cord grips provide a path for contaminates to leak into the enc...

Страница 7: ... begin operating the Signal Conditioner s Make sure the status light is indicating normal mode on each SC200 Operating Procedure To operate the Signal Conditioners inside the enclosure make sure that all wires are properly connected then apply power CAUTION Make sure that power input does not exceed specified limits or damage to the system may result See Table 1 Calibration The Signal Conditioner ...

Страница 8: ... 0 5 second intervals Errors can be due to o Input Sensor bias voltage 5 V Sensor is considered shorted o Input Sensor bias voltage 15 V Sensor is considered unconnected missing o Invalid configuration of switch settings Portable Data Collector Interfacing In order to collect waveform data from the BNC jack on the Signal Conditioner using a portable data collector that supplies constant current po...

Страница 9: ...hould ever fail we will repair or replace it at no charge as long as the product was not subjected to misuse natural disasters improper installation or modification which caused the defect CONTACT INFORMATION Connection Technology Center Inc CTC 7939 Rae Blvd Victor NY 14564 1 800 999 5290 US Canada 1 585 924 5900 International sales ctconline com www ctconline com Section IV Maintenance ...