![CTC Union XE150 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/ctc-union/xe150/xe150_product-manual_2693296004.webp)
MNX10030 Rev 0
8/20/2008
3
POWER INPUT:
100-240 VAC, .68A, 50–60 Hz
BANDPASS FILTER:
The Signal Conditioners contain a band-pass filter, which
consists of 10 low-pass (50 Hz to 15 kHz) and 8 high-pass
(5 Hz to 1000 Hz).
DIGITAL OUTPUT:
Full scale output of 4-20 mA for Vibration and Temperature.
Selectable 0-5 or 0-10 VDC output for signal vibration
OPERATION:
Accepts a Signal input, filters the signal, and normalizes the
output to the specified full-scale output. Performs a true
RMS conversion (if needed) and transmits this data into
specified output.
ENCLOSURE
DIMENSIONS:
Small Enclosure (1-6 Channels) – 12” x 10” x 6 ½”
Large Enclosure (6-12 Channels) – 16” x 14” x 8 ¼”
TEMPERATURE RATING
OF ENCLOSURE
-50 degrees F to + 180 degrees F
ENCLOSURE RATING:
NEMA 4X
Table 1. Specifications
•
Specifications on a particular Signal Conditioner may be obtained from the unit's
label or by calling an Application Engineer for more information.
Selection Guide
Below is a guide to help select which XE150 series enclosure fits your specific
requirements.