
Chapter 2 Provisioning
21
Ping the
NMC
from the TFTP server PC
and be sure there is a response.
Place the upgrade file(s) in the same folder
as the TFTP server program.
Start the TFTP server on the connected PC.
In our example, we are using the CTC Union
TFTP server. If Windows® is running a firewall,
a security alert will popup. Click the "Unblock"
button to allow TFTP protocol from the
CTCUTftpServer application.
From the console terminal menu, select "9"
to upgrade the kernel (very rare) or "A" to
upgrade the filesystem (more likely).
The screen at the left shows that the
romfs.zip file was transferred OK.
Note: Use the console menu items 6&7 to
set the filenames for the kernel and/or
filesystem if they do not match the upgrade file
names.
You may now 'Close' the TFTP server on
the PC.
Содержание FRM220-NMC
Страница 1: ...FRM220 NMC Network Management Controller...
Страница 2: ......
Страница 7: ...Table of Contents iii...
Страница 8: ......
Страница 104: ...Appendix A 102 A 3 FRM220 FXO FXS In band Managed POTS PSTN Fiber Converter...
Страница 105: ...Appendix A 103...
Страница 180: ......
Страница 181: ......
Страница 182: ......