Appendix A
138
A.7.15 Date & Time Setup
The date and time setup are important so that any trap messages generated by the SNMP agent will have the
correct timestamp. The
10/100A
supports setting time manually or automatic time configuration through the use of
NTP
(Network Time Protocol) or
SNTP
(Simple Network Time Protocol).
From the Main Menu, select the <S> (System Configuration) and from this menu select <T> (Date and Time).
1.
Adjust Current Time
– Use this menu item to manually adjust the date and time.
2.
Set Time Server IP
– The time server IP is the IP address of a NTP server that provides time synchronization services on a
network. Geographically close servers should be chosen from the pool of NTP servers.
3.
Set Time Zone
– All network time is synchronized to UTC (Coordinated Universal Time) which is based on International
Atomic Time. The time zone setting will let the UTC time appear correctly for your geographic location. Time zone settings
are + (East) or – (West) full or half hours from UTC coordinates or previously known as GMT (Greenwich Mean Time).
4.
Enable/Disable Auto Synchronize Time
– When auto synchronization is enabled, the SNTP daemon in the
1000EAS
will
poll and update time from the time server once every hour.
5.
Synchronize Time with NTP Server
– This action will cause the SNTP daemon to immediately poll and update date and
time with the NTP server. The results will either be a 'timeout' or the time will be successfully synchronized.
A.7.16 Password Setup
Access to the
10/100A
via Telnet or Web is controlled by the use of user passwords. One user ID account can
be created and assigned password for authentication. The management interface can only then be accessed by
using the correct username and password.
From the Main Menu, select the <S> (System Configuration) and from this menu select <L> (Password Setting).
1.
Login Password
– Enable or disable the password authorization feature.
2.
Set New UID and Password
– Key-in username and password for management authentication.
If the password is lost, the unit must be reset to factory default. See section 1.7.
*************************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220-10/100A ver:3.016 ***
*************************************************
<< Date and Time >>
Current Date And Time [2010-05-21/12:44:53 Fri]
Time Server IP [220.130.158.71]
Time Zone [GMT +08:00]
Auto Adjust Time [Enable ]
<1> :Adjust Current Time.
<2> :Set Time Server IP.
<3> :Set Time Zone.
<4> :Enable/Disable Auto Synchronize Time.
<5> :Synchronize Time with NTP Server.
<ESC>:Go to Previous Menu.
*************************************************
*** CTC UNION TECHNOLOGIES CO., LTD. ***
*** FRM220-10/100A ver:3.016 ***
*************************************************
<< Password Configuration >>
<1> :Login Password [Disable]
<2> :Set New UID and Password.
<ESC>:Go to Previous Menu.
Содержание FRM220-NMC
Страница 1: ...FRM220 NMC Network Management Controller...
Страница 2: ......
Страница 7: ...Table of Contents iii...
Страница 8: ......
Страница 104: ...Appendix A 102 A 3 FRM220 FXO FXS In band Managed POTS PSTN Fiber Converter...
Страница 105: ...Appendix A 103...
Страница 180: ......
Страница 181: ......
Страница 182: ......