-13-
Operation
Initial Operation
Do not subject the measuring tool to extreme
temperatures or variations in temperature.
As an example, do not leave it in vehicles
for long time. In case of large variations in
temperature, allow the measuring tool to adjust
to the ambient temperature before putting it into
operation. In case of extreme temperatures or
variations in temperature, the accuracy of the
measuring tool can be impaired.
Avoid heavy impact to or falling down of the
measuring tool. After severe exterior effects to
the measuring tool, it is recommended to carry
out an accuracy check (see “Accuracy Check of
the Measuring Tool”, page 16) each time before
continuing to work.
Setting Up the Measuring Tool
Position the measuring tool on a firm surface
in the horizontal or vertical position, mount it to
a tripod or to the wall mount
26
with alignment
unit. Due to the high leveling accuracy, the
measuring tool reacts sensitively to ground
vibrations and position changes. Therefore,
pay attention that the position of the measuring
tool is stable in order to avoid operational
interruptions due to re-leveling.
Switching On and Off
To switch on the measuring tool, press the On/
Off button
2
. This is confirmed by brief flashing
of all indicators.
– RL25H: Immediately after switching on, the
measuring tool
laser beam
14
flashes.
– RL25HV: Immediately after switching on, the
measuring tool laser beam
14
and
the plumb
beam
15
flash. Do not point the laser beam at
persons or animals and do not look into the
laser beam yourself, not even from a large
distance. The measuring tool immediately starts
automatic leveling after switching on. During
leveling, the leveling indicator
3
flashes green,
the laser flashes.
The measuring tool is leveled in as soon as
leveling indicator
3
continuously lights up green
and the laser beam is steady. The measuring
tool automatically starts in rotational operation,
the ADS function is switched on (ADS indicator
7
lights up green).
To switch off the measuring tool, press the On/
Off button
2
again.
Do not leave the switched on measuring tool
unattended and switch the measuring tool off
after use. Other persons could be blinded by the
laser beam.
When not using the measuring tool, switch it off
in order to extend the battery life.
The measuring tool is switched off automatically
to extend the battery life
–When not within the self-leveling range for
more than 30 minutes
– When the ADS function has been actuated
longer than 2 h
– When it is not switched on again within 2 h
while in hibernation mode (only possible with
remote control).
If required, reposition the measuring tool and
switch it on again.
Hibernation Mode with Storage of the
Operating Mode
With the remote control
24
, the measuring
tool can be switched to hibernation mode to
conserve energy. This is confirmed by flashing
of the power LED
3
.
The operating mode set on the measuring tool
is retained. When the ADS function is switched
on, the position of the measuring tool is also
monitored during hibernation mode.
To end hibernation mode, press any button on
the remote control or the keypad
Horizontal position
(RL25H/RL25HV)
Vertical position
(RL25HV)
Содержание rl25h
Страница 2: ...2 1 1 2 3 4 5 3 2 8 7 6 6 16 12 14 13 1 13 15 11 10 9 12 11 10 9 8 7 RL25HV RL25H...
Страница 3: ...3 16 7 1 19 18 20 RL25H RL25HV...
Страница 4: ...4 22 23 28 21 24 27 26 25...
Страница 5: ...5 22 21 24 23...
Страница 6: ...6...
Страница 7: ...7 H G...
Страница 17: ...17 RM7 Remote Control RM7 7 1 2 8 9 10 11 3 4 5 6 12 13 14...
Страница 23: ...23 RD5 4 14 13 3 2 1 10 11 7 6 5 8 9 8 4 12 17 16 19 18 20 15 A b a c f d e g h RD5 Detector...
Страница 41: ...41 B A 50 ft B A 180 B A A d B 180...
Страница 65: ...65 B A 50 ft B A 180 B A A d B 180...