![CSI VCC-HD3 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/csi/vcc-hd3/vcc-hd3_product-specification-and-operational-manual_2692609010.webp)
VCC-HD3 Rev. 905-0051-Z0
©2016 CIS Corporation. All rights reserved.
9
9.
Defective Pixel Correction
9.1.
Precautions
When the user executes Defective Pixel Correction and “SAVE”, the data at the factory setting will be over-written, so that
the data cannot be back to the factory setting data even when “INIT” command was executed. Execute “INIT”, then
“SAVE” to overwrite the preset data (camera settings) with the factory setting data.
If you do not wish to overwrite the preset data, load the preset data before executing SAVE. The defective pixel
correction data will be saved in one area regardless of its preset number.
Since the function only supports the white defects correction, the black defects cannot be corrected. And, the function
is not necessarily able to correct all the white defects. In addition, due to the effect from the noise or the temperature
conditions, the correction result may not be always the same.
Please be noted that improper command execution such as under no light-blocking, or taking wrong procedure, may
cause incorrect operation of the executed command function or abnormal images.
9.2.
How to execute “Defective Pixel Correction”
・
Execute “INIT” to return to the factory settings.
・
Attach the bundled cap to the lens mount for light-blocking, then wait for about 5 seconds..
・
Execute “Defective Pixel Correction” and SAVE.