2
© Gamajet Cleaning Systems, Inc. 10/24/01
joint tape prior to mounting. This will minimize any chance of leakage and will
make subsequent removal much easier.
1.2.3 MOUNTING
While the dual nozzle unit is hydraulically balanced, the Gamajet V should be
mounted on a rigid pipe. In most applications, the Gamajet V will be mounted in
the "upright" position (inlet connection pointing up); however, if required, the
Gamajet will function equally well inverted or horizontally. We do not
recommend this form of mounting since the hose is not rigid and, thus, will not
maintain the Gamajet's position should it become unbalanced due to clogging of
the nozzles.
NOTE:
When attaching the Gamajet V onto the supply pipe, ALWAYS use the
wrench flats on the Inlet Collar at the top or inlet of the unit.
Never place the
wrench on the outside of the gearbox, or bottom, of the unit to tighten the
unit onto the pipe.
If you do, you'll unscrew the unit or break internal screws or
both.
1.2.4 LOCATION INSIDE THE TANK
Generally, a single Gamajet should be positioned in the approximate center of the
tank in order to equalize the cleaning radius in all directions. Some tanks may
have specific cleaning problems such as coils or heavy deposits such as the liquid
level line (bathtub ring). In these situations the Gamajet will need to be located
closer to the difficult area for the best cleaning results.
Tanks with internal mechanisms or structures such as an agitator shaft or
impellers or baffles will require careful positioning to minimize the "shadow" on
areas which do not receive direct jet impact. Sometimes, more than one machine
or more than one placement of a single machine may be necessary to completely
avoid shadow problems or “striping.”
Refer to Appendix A for dimensions describing the Gamajet's operating
clearances.
1.2.5 ENTRY OPENINGS
When using the Gamajet V, the tanks being cleaned must provide entry openings
large enough to avoid interference during insertion and removal. The minimum
opening size required for the Gamajet V is 3.0 inches in diameter (76.2 mm).
1.2.6 DRAINAGE
If it is necessary to clean the floor of a tank, remember that standing liquid will
diminish the effectiveness of the jet by covering any soils underneath. Wherever
possible, the tank floor should be pitched toward the drain and the drainage
opening should be large enough to eliminate or reduce any liquid buildup or
puddling. If gravity alone is insufficient, a scavenger or stripper pump should be
Содержание GamaJet V
Страница 27: ...GAMAJET V UPDATE ASSEMBLY PROCEDURE EXPLODED VIEW ...
Страница 29: ...STEP 2 GAMAJET V GEAR TRAIN ASSEMBLY EXPLODED VIEW 8 541 8 511 AS 8 522 AS 8 513 8 514 3 4 6 8 23 8 512 5 ...
Страница 30: ...STEP 3 GAMAJET V GEARBOX ASSEMBLY EXPLODED VIEW GEAR TRAIN ASSEMBLY 8 501 8 530 1 2 ...
Страница 35: ...STEP 7 GAMAJET V NOZZLE HOUSING ASSEMBLY EXPLODED VIEW 8 505 AS 8 507 AS 8 518 8 519 41 42 45 8 549 49 ...