SIGNATURE SERIES
9
Service Information
-Home Display-
UnT1
MENU / ENTER
Button
SET / CHANGE
Button
• Alternates between indicating which unit is in service (currently being used to soften the water) and how many gallons
are remaining before that unit needs regenerated. If Softener Slave Unit #1 is in service the display will show [Unt1].
If Softener Slave Unit #2 is in service the display will show [Unt2].
• The gallons remaining will decrease as water is used. Once the gallons remaining gets to [0000] the shuttle valve will
automatically switch the water flow to the Unit that is in standby.
• During the time that the shuttle valve is shuttling, the display will show the number of the softener unit that it is shuttling
to and the last two digits will show rotating segments (ex. [2-'']).
• Once done shuttling the display will again show the Softener Unit that is in service and the gallons remaining. The
softener Unit that was just taken out of service will begin its regeneration cycle.
• To view the status of the standby unit, press and release the
MENU / ENTER
button. The display will alternate between
the unit number and it’s status:
○
If the status shows “
rdy
”, this means that the standby unit is ready to go into service when needed
○ If the standby unit is currently regenerating, the display will show the cycle step and the number of minutes
remaining (example: 1 - 10)
-Main Menu-
• To enter main menu, press the
MENU / ENTER
button.
• The first menu item is the hardness setting. (ex. [H-25]). The hardness setting should be set according to the water
hardness of the water being treated. The hardness setting is used to calculate the number of gallons of water that can
be treated between softener unit regenerations.
o To edit this setting Press the
SET / CHANGE
button.
o The lowest digit will begin flashing while the other digits are solid.
o Press
SET / CHANGE
to change the digit to the desired value.
o Press
MENU / ENTER
to accept the value of the current digit.
o Repeat last two steps for each digit. o Once the last digit is accepted all digits will flash.
*The hardness setting is the only programming necessary upon installation.
• To continue to the next menu item press the
MENU / ENTER
button.
• The third menu item is the regeneration day override setting and will show the current setting (ex. [
A-07
], the entire
display will be flashing. This setting adjusts the number of days between forced regenerations (if the unit has not been
regenerated because of normal water usage). This number will get reset to the programmed setting after any
regeneration, and will count down once every 24 hours. If it reaches zero it will force the shuttle valve to switch softener
units and will begin regeneration of the unit that leaves service
• To edit this setting Press the
SET / CHANGE
button.
• The lowest digit will begin flashing while the other digits are solid.
• Press
SET / CHANGE
to change the digit to the desired value. o Press MENU ENTER to accept the value of the current
digit
• Repeat last two steps for each digit.
• Once the last digit is accepted all digits will flash.
Notes: - Maximum Value is 29.
- If value is set to 0, regeneration override will never occur
• To exit the Main Menu press the
MENU / ENTER
button.
Note:
While in any part of the Main Menu, if no buttons are pressed for 60 seconds or longer the menu will automatically
be exited.