Safety instructions 

DP400 mobil V1.00 EN 

Seite 4 von 15 

1.2 

   Installation 

NOTE! 

 

The plug of the power supply unit (charger) is used as a separator. 

This separator must be clearly recognisable and easily accessible by the user. A 
plug connector with a CEE7/7 system is necessary. 

NOTE! 

 

Only the supplied power supply may be used. 

1.3 

 Lithium Ion Batterie 

Warning! 

Battery! 

The replacement of the battery must only be carried out by authorised and 
skilled personnel, and when the device is de-energised. 

Only the original battery of the manufacturer with built-in protection circuit 
may be used. 

Do not use any other power supply for charging the Li-Ion battery as the provided.

Do not charge the battery under conditions that are not specified in the manual.

Do not charge the battery in an environment with flammable substances. Never charge the
battery unattended.

Transport

The contained lithium ion batteries are subject to the Dangerous Goods Legislation requirements. The user
can transport the batteries by road without further requirements.
When being transported by third parties (e.g.: air transport or forwarding agency), special requirements on
packaging and labelling must be observed. For preparation of the item being shipped, consulting an expert
for hazardous material is required.
Please also observe possibly more detailed national regulations.

    Disposal 

The datalogger, rechargeable batteries, accessories and packaging should be sorted for  
environmental friendly recycling. 
Do not dispose of power tools and batteries/rechargeable batteries into household waste! 

Only for EC countries: 

According to the European Guideline 2012/19/EU, power tools that are no longer 
usable, and according to the European Guideline 2006/66/EC, defective or used 
battery packs/batteries, must be collected separately and disposed of in an environmentally 
correct manner. 

Batteries no longer suitable for use can be directly returned at: 

CS Instruments GmbH & Co.KG 
Zindelsteiner Str. 15  
D-78052 VS-Tannheim

CS Instruments GmbH & Co.KG 
Am Oxer 28c  
D-24955 Harrislee

Содержание DP 400 mobil

Страница 1: ...DP 400 mobil V1 00 EN Seite 1 von 15 Installation and operating instructions portable dew point meter with integrated pressure measurement DP 400 mobil EN English...

Страница 2: ...vour of the DP 400 mobil Please read this installation and operation manual carefully before mounting and initiating the device and follow our advice A riskless operation and a correct functioning of...

Страница 3: ...nsors 7 6 Cable cross section 7 6 1 Sensor circuit points Output signal 7 7 Installation Connection Measurement 8 7 1 User controls connection 8 7 1 1 Dew point measurement 8 7 1 2 Display Datalogger...

Страница 4: ...ons e g VDE 0100 Carry out maintenance only in strain less state All electric works are only allowed to be carried out by authorized qualified personnel Warning Inadmissible operating parameters Under...

Страница 5: ...the Dangerous Goods Legislation requirements The user can transport the batteries by road without further requirements When being transported by third parties e g air transport or forwarding agency s...

Страница 6: ...measured values of storage capacity Any analogue sensors 0 4 20 mA 0 1 10 30 V pulse are easy and fast to configure Digital sensors can be connected via RS 485 Modbus RTU Optional Network capable and...

Страница 7: ...point 1 C for 20 20 Ctd 2 C for 20 50 Ctd 3 C for 50 80 Ctd Accuray pressure 0 5 Power supply for sensors Output voltage 24 VDC 10 Output current a Digital board 120 mA continuous operation b Analogu...

Страница 8: ...y 0 03 mA 0 05 Input resistance 50 Voltage signal 0 1V Measuring range 0 1 V Resolution 0 05 mV Accuracy 0 2 mV 0 05 Input resistance 100 k Voltage signal 0 10 V 30 V Measuring range 0 10 V 30 V Resol...

Страница 9: ...0 EN Seite 8 von 15 7 Installation Connection Measurement 7 1 User controls connection 7 1 1 Dew point measurement Plug in connection Medium closed with red seal plug Medium output Control Medium on o...

Страница 10: ...ob during operation opens a popup with indication of the remaining operation time The data logger is operated via the touchpanel integrated in the display 7 1 3 Sensor connections Power supply connect...

Страница 11: ...vice is compromised Before disconnecting the DP 400 mobile from the gas line it is necessary to vent the system to atmospheric pressure otherwise serious injuries may occur Note At delivery the dew po...

Страница 12: ...ng point should be as close as possible to the critical measuring point in order to obtain a truly representative measurement The length of the DP 400 mobile cable should be as short as possible Only...

Страница 13: ...ld be activated between the measurements or especially during longer periods of interruption and storage This is to protect the moisture sensor from excessively high moisture and thus to ensure fast r...

Страница 14: ...sharp edges The foil can be damaged The DP 400 mobile is pre configured i e the pressure dew point temperature pressure as well as rel humidity are displayed directly on the start screen Configuratio...

Страница 15: ...oap For decontamination spray the cleaner on an unused cotton cloth or one way wipe and wipe the component comprehensively Perform the final drying with a clean cloth or by air drying In addition the...

Отзывы: