5  Input signals analogue sensors 

6  Cable cross-section 

6.1 

  Sensor circuit points/Output signal 

ODU Medi-Snap, AWG26 cable cross-sections: 0,14 mm

Input signal 

Current signal 
(0 

– 20 mA / 4 – 20 mA) 

internal or external    
power supply 

Measuring range 

– 20 mA / 4 – 20 mA 

Resolution 

0,0001 mA 

Accuracy 

 0,03 mA 

 0,05 % 

Input resistance 

50 

 

Voltage signal 
(0 - 1V) 

Measuring range 

0 - 1 V 

Resolution 

0,05 mV 

Accuracy 

 0,2 mV 

 0,05 % 

Input resistance 

100 k

 

Voltage signal 
(0 - 10 V / 30 V) 

Measuring range 

0 - 10 V/30 V 

Resolution 

0,5 mV 

Accuracy 

  2 mV 

  0,05 % 

Input resistance 

1 M

 

RTD 
Pt100 

Measuring range 

-200 - 850 °C

Resolution 

0,1 °C 

Accuracy 

 0,2 °C at -100 - 400 °C 

 0,3 °C (further range) 

RTD 
Pt1000 

Measuring range 

-200 - 850 °C

Resolution 

0,1 °C 

Accuracy 

 0,2 °C at -100 - 400 °C 

 0,3 °C ( further range )

 

Pulse 

Measuring range 

minimal pulse length 100 

μs 

frequency 0 - 1 kHz    
max. 30 VDC 

Содержание DP 400 mobil

Страница 1: ...DP 400 mobil V1 00 EN Seite 1 von 15 Installation and operating instructions portable dew point meter with integrated pressure measurement DP 400 mobil EN English...

Страница 2: ...vour of the DP 400 mobil Please read this installation and operation manual carefully before mounting and initiating the device and follow our advice A riskless operation and a correct functioning of...

Страница 3: ...nsors 7 6 Cable cross section 7 6 1 Sensor circuit points Output signal 7 7 Installation Connection Measurement 8 7 1 User controls connection 8 7 1 1 Dew point measurement 8 7 1 2 Display Datalogger...

Страница 4: ...ons e g VDE 0100 Carry out maintenance only in strain less state All electric works are only allowed to be carried out by authorized qualified personnel Warning Inadmissible operating parameters Under...

Страница 5: ...the Dangerous Goods Legislation requirements The user can transport the batteries by road without further requirements When being transported by third parties e g air transport or forwarding agency s...

Страница 6: ...measured values of storage capacity Any analogue sensors 0 4 20 mA 0 1 10 30 V pulse are easy and fast to configure Digital sensors can be connected via RS 485 Modbus RTU Optional Network capable and...

Страница 7: ...point 1 C for 20 20 Ctd 2 C for 20 50 Ctd 3 C for 50 80 Ctd Accuray pressure 0 5 Power supply for sensors Output voltage 24 VDC 10 Output current a Digital board 120 mA continuous operation b Analogu...

Страница 8: ...y 0 03 mA 0 05 Input resistance 50 Voltage signal 0 1V Measuring range 0 1 V Resolution 0 05 mV Accuracy 0 2 mV 0 05 Input resistance 100 k Voltage signal 0 10 V 30 V Measuring range 0 10 V 30 V Resol...

Страница 9: ...0 EN Seite 8 von 15 7 Installation Connection Measurement 7 1 User controls connection 7 1 1 Dew point measurement Plug in connection Medium closed with red seal plug Medium output Control Medium on o...

Страница 10: ...ob during operation opens a popup with indication of the remaining operation time The data logger is operated via the touchpanel integrated in the display 7 1 3 Sensor connections Power supply connect...

Страница 11: ...vice is compromised Before disconnecting the DP 400 mobile from the gas line it is necessary to vent the system to atmospheric pressure otherwise serious injuries may occur Note At delivery the dew po...

Страница 12: ...ng point should be as close as possible to the critical measuring point in order to obtain a truly representative measurement The length of the DP 400 mobile cable should be as short as possible Only...

Страница 13: ...ld be activated between the measurements or especially during longer periods of interruption and storage This is to protect the moisture sensor from excessively high moisture and thus to ensure fast r...

Страница 14: ...sharp edges The foil can be damaged The DP 400 mobile is pre configured i e the pressure dew point temperature pressure as well as rel humidity are displayed directly on the start screen Configuratio...

Страница 15: ...oap For decontamination spray the cleaner on an unused cotton cloth or one way wipe and wipe the component comprehensively Perform the final drying with a clean cloth or by air drying In addition the...

Отзывы: