Crystal Vision
Hardware installation
Up-and-down-AAFD User Manual R1.2
9
17/11/10
4U frame GPI connections
GPI lines ‘a’ to ‘f’ of each card connect to two of eight rear remote connectors as follows:
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
8 (1)
9 (1)
18 (1)
26 (1)
19 (2)
20 (2)
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
3
8 (3)
9 (3)
18 (3)
26 (3)
19 (4)
20 (4)
4
7 (3)
16 (3)
17 (3)
25 (3)
10 (4)
11 (4)
5
5 (1)
6 (1)
15 (1)
24 (1)
1 (2)
2 (2)
6
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
7
5 (3)
6 (3)
15 (3)
24 (3)
1 (4)
2 (4)
8
4 (3)
14 (3)
13 (3)
23 (3)
3 (4)
4 (4)
9
3 (1)
12 (1)
22 (1)
21 (1)
12 (2)
13 (2)
10
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
11
3 (3)
12 (3)
22 (3)
21 (3)
12 (4)
13 (4)
12
10 (3)
11 (3)
19 (3)
20 (3)
21 (4)
22 (4)
Table shows pin number (remote number)
Slot no.
‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
8 (5)
9 (5)
18 (5)
26 (5)
19 (6)
20 (6)
2
7 (5)
16 (5)
17 (5)
25 (5)
10 (6)
11 (6)
3
8 (7)
9 (7)
18 (7)
26 (7)
19 (8)
20 (8)
4
7 (7)
16 (7)
17 (7)
25 (7)
10 (8)
11 (8)
5
5 (5)
6 (5)
15 (5)
24 (5)
1 (6)
2 (6)
6
4 (5)
14 (5)
13 (5)
23 (5)
3 (6)
4 (6)
7
5 (7)
6 (7)
15 (7)
24 (7)
1 (8)
2 (8)
8
4 (7)
14 (7)
13 (7)
23 (7)
3 (8)
4 (8)
9
3 (5)
12 (5)
22 (5)
21 (5)
12 (6)
13 (6)
10
10 (5)
11 (5)
19 (5)
20 (5)
21 (6)
22 (6)
11
3 (7)
12 (7)
22 (7)
21 (7)
12 (8)
13 (8)
12
10 (7)
11 (7)
19 (7)
20 (7)
21 (8)
22 (8)
Table shows pin number (remote number)
Note:
Remote 1, Remote 3, Remote 5 and Remote 7 are 26-way high-density D-Type female
sockets. Frame ground is pin 2 and +5V @500mA is pin 1 in each case.
Remote 2, Remote 4, Remote 6 and Remote 8 are 26-way high-density D-Type male plugs
and frame ground is pin 6 in each case and +5V @500mA is pin 15 on Remote 2 and
Remote 6.
Note. The +5V output is protected by self-resetting thermal fuses, which limit the total
output current available from Remotes 1-4 to approximately 1A. Remotes 5-8 are similarly
protected.
Upper