Crystal Vision
Statesman
Tip. Zero delay can be obtained by setting the sliders for one full frame of
delay minus 2 samples
The variable assigned is always shown in the top line of the slider display. It is
not possible to assign a delay beyond the range indicated by the slider. If a
value less than the minimum or greater than the maximum is assigned, the
slider will automatically jump to the minimum or maximum value i.e. the
maximum NTSC delay is 524 lines and 1715 samples (pixels)
The delay controls may be a set in several different ways. The slide can be
clicked and dragged, the numerical display may be edited or by clicking on
the selected position on the scale, the slider will jump to the value
corresponding to that position.
The sliders may be reset to their default values at any time by clicking on the
Cal button below each slider.
Output Colour
The output colour can be set to either Black or Blue by checking the
appropriate radio button.
Output Standard
In free-running mode i.e. no external reference present, the output standard
may be selected by checking the appropriate radio button.
Video status
The Input Present indicator will illuminate green when an external reference is
present or red if missing.
The video standard of the external reference is automatically detected and is
shown by a yellow indicator. The reference output will automatically follow
the reference input irrespective of the output standard selection.
Further status information is provided by the Statesman logging and alarms
feature, which is described in more detail in the Statesman manual.
Reset
Selecting reset will return variables to their default values. The output
standard will depend on the presence of an input.
REFGEN User Manual R2.0
21
11 January 2019