Crystal Vision
Using the active front panel
4.3 Control menu
The control menu is where the output colour and line standard can be set.
REFGEN control menu
Description
To select the control menu, press F1 to
activate. Selection is made by rotation of
the shaft control. Press Enter to make
selection.
To select the output colour, press F2 to
activate. Selection is made by rotation of
the shaft control. Press Enter to make
selection.
Black, Blue.
To select the output line standard, press F2
to activate. Selection is made by rotation of
the shaft control.
Press Enter to make selection.
525 Lines, 625 Lines, IP Pres no control.
Note:
Output line standard is only available in free-running mode.
4.4 Adjusting delay time
Pressing F2 from the home menu will bring up the delay menu. The delay menu
provides access to the delay settings available when an external reference is
present. Rotate the shaft encoder to select each sub-menu and also change
parameters.
REFGEN delay menu
Description
From the Home menu, press F2 to select the
delay menu, which is then traversed by rotating
the shaft control. Note: Delay settings are only
valid if an external reference is present.
Rotate shaft encoder to select the Lines delay.
Press F2 to select to change the value.
Rotate shaft encoder to set the new value. Press
enter to accept the new value.
NTSC
0-524,
PAL
0-624.
Rotate shaft encoder to select the Samples delay.
Press F2 to select to change the value.
Rotate shaft encoder to set the new value. Press
enter to accept the new value.
NTSC
0-1715,
PAL
0-1725.
REFGEN User Manual R2.0
16