Crystal Vision
Introduction
ADP 310 Functional Block Diagram
Block Diagram Description
All analogue or digital audio is passed to audio processing blocks where gain and
delay adjustments are made after resampling. Dolby E encoded signals
automatically bypass the audio processing stage.
The outputs of the audio processing block are inputs to an 8x8 router which feeds
the plug-in output piggyback. In this way any of the eight digital channels or four
analogue channels can be routed to any output channel.
An analogue Black and Burst or tri-level syncs reference must be applied to provide
a stable clock to lock to the incoming AES and analogue audio.
ADP 310 User Manual R1.2
5
19 June 2019