Operation Manual
I-Tech HD DriveCore Series
Power Amplifiers
page 24
7 Advanced Operation
Low Limit Load errors:
This screen lets you view low-load errors without
using the control software. A
low limit load error
occurs if the load
impedance falls below the value set with the
Low Limit spin control
on the
Amplifier Settings page in System Architect.
When an error occurs, the count displayed in this screen is incremented, and
the operating time since the error is displayed.
To clear this screen, press a channel icon.
NOTE: You must use System Architect to enable error reporting and set its
limits.
High Limit Load errors:
This screen lets you view high limit load errors
without using the control software. A
high limit load error
occurs if the load
impedance rises above the value set with the
High Limit
value
on the
software Control Panel.
When an error occurs, the count displayed in this screen is incre mented, and
the operating time since the error is displayed.
To clear this screen, press a channel icon
NOTE: You must use System Architect to enable error report ing and set its
limits.
Fan errors:
When a fan error occurs, the count displayed in this screen is
incre mented, and the operating time since the error is displayed.
clear All error Logs:
In this screen, you can press and hold an the icon to
clear all the error logs.
Line Voltage errors:
This screen lets you view line-voltage errors without
using the control software. A
line voltage error
occurs if the line voltage falls
outside the values set with the
High/Low Limits slider
on the Line Voltage
Page of the Control Panel.
When an error occurs, the count displayed in this screen is incre mented, and
the operating time since the error is displayed. The “Low” and “High”
indicators show whether the line voltage was below or above the line-voltage
limits.
To clear this screen, press the icon. (The display will prompt you to confirm
your choice by pressing and holding the Encoder.)
NOTE: You must use System Architect to enable error report ing and set its
limits.
SLM (Sweep Load Monitoring) errors:
This screen lets you view SLM
errors without using the control software.
When an error occurs, the count displayed in this screen is incremented, and
the operating time since the error is displayed.
To clear this screen, press and release an Encoder. The display will prompt you
to confirm your choice by pressing and holding the Encoder.
NOTE: You must use System Architect to enable error reporting and set its
limits.