15
TABLE 7.4a: CROWN CONCENTRIC 60/100 VENT COMPONENTS
(VENT OPTION 1)
CROWN PN
DESCRIPTION
SIZE
USED ON
VENT
OPTION #
COMMENTS
230521
80/125 x 60/100mm REDUCING
ELBOW
80/125 x
60/100mm
1
INCLUDED WITH STANDARD
BWC070/090/120
230520
TERMINAL SECTION
60/100mm
1
INCLUDED WITH STANDARD
BWC070/090/120
230522
WALL GROMMET
60/100mm
1
INCLUDED WITH STANDARD
BWC070/090/120
230505
39” STRAIGHT
60/100mm
1
OPTIONAL - MAY NOT BE CUT
230504
78” STRAIGHT
60/100mm
1
OPTIONAL - MAY NOT BE CUT
230506
19 1/2” STRAIGHT
60/100mm
1
OPTIONAL - CAN BE CUT
230507
90 DEGREE ELBOW
60/100mm
1
OPTIONAL
230508
45 DEGREE ELBOW
60/100mm
1
OPTIONAL
230515
39” STRAIGHT
80/125mm
1
OPTIONAL - CAN BE CUT (Note #1)
Note #1: On 60/100mm vent systems, this may only be used between the boiler and the first 80/125 x 60/100 Reducing elbow (see text).
TABLE 7.4b: CROWN CONCENTRIC 80/125 VENT COMPONENTS
(VENT OPTIONS 3,6)
CROWN PN
DESCRIPTION
SIZE
USED ON
VENT
OPTION #
COMMENTS
230527
90 DEGREE EL (STANDARD)
80/125mm
3,6
230528
90 DEGREE EL (SWEEP)
80/125mm
3,6
230526
45 DEGREE EL
80/125mm
3,6
230517
19 1/2” STRAIGHT
80/125mm
3,6
CAN BE CUT
230515
39” STRAIGHT
80/125mm
3,6
CAN BE CUT
230518
39” STRAIGHT
80/125mm
3,6
MAY NOT BE CUT
230519
78” STRAIGHT
80/125mm
3,6
MAY NOT BE CUT
230525
TELESCOPING STRAIGHT
80/125mm
3,6
ADJUSTABLE FROM 12-1/2” TO 16-1/2
230531
HORIZONTAL TERMINAL
80/125mm
3
230540
SNORKEL KIT
80/125mm
3
(NOTE #1)
230532
VERTICAL TERMINAL
80/125mm
6
(NOTE #2)
230533
FLAT ROOF FLASHING
80/125mm
6
230535
SLOPED ROOF FLASHING
80/125mm
6
(NOTE #3)
230530
SUPPORT ELBOW WITH
CHIMNEY CHASE BRACKET
80/125mm
6
(NOTE #4)
230536
SUPPORT BAND
80/125mm
3,6
Table 7.4b Notes:
1) Snorkel kit includes parts needed to offset terminal on exterior wall by up to
46”.
2) Vertical terminal can be used with either of the roof flashings listed beneath it.
3) Sloped roof flashing suitable for roof angles between 25 and 45 degrees.
4) Used at base of vertical run inside unused masonry chimney.
Содержание BIMINI BUDDY BWC090
Страница 2: ......
Страница 9: ...7 Figure 5 1 Wall Mounting Hole Locations ...
Страница 10: ...Figure 5 2 Boiler Mounting Hardware 8 ...
Страница 25: ...FIGURE 7 21 DIMENSION L 23 FIGURE 7 20 INSTALLATION OF REDUCING ELBOW ON CONCENTRIC BOILER COLLAR ...
Страница 35: ...FIGURE 7 35b CUTTING VERTICAL TERMINAL FIGURE 7 35c COMPLETING VERTICAL TERMINAL INSTALLATION 33 ...
Страница 43: ...FIGURE 7 51 CONDENSATE PIPING ARRANGEMENT 41 ...
Страница 56: ...54 Figure 10 1 Wiring Connections Diagram ...
Страница 57: ...55 Figure 10 2 Ladder Diagram ...
Страница 58: ...56 Figure 10 3 Wiring of Isolation Relay for Control of Two Heating Circulators ...
Страница 76: ...74 ...
Страница 79: ...77 ...
Страница 80: ...78 ...
Страница 81: ...79 ...
Страница 82: ...80 ...
Страница 84: ...82 150 151 152 153 154 155 ...
Страница 85: ...83 156 157 158 159 160 161 ...
Страница 86: ...162 84 ...