background image

 

 

Operating the Keypad 

How to Arm the System before Exit 

Preparing the System for Arming 

Verify that all zone indicators are off, when all zones are closed (all doors, exits and windows are 

closed and motion in the protected area is restricted or bypassed), the system is ready to be 

armed. If one or more zone indicators are illuminated, it displays the open zones. 

When system is ready, there is ready indication 

light at green. 

  
Close open zones, or bypass them. Bypass any zone you cannot close. To see which zones 

are in bypass mode, press 

  or  

 

Note: Bypassed zones are not protected. 

Arming the System 

Before leaving premises you must arm the system. 

Arming the alarm system turns on all detectors in the partition/s being armed.  

1.  Enter your code.  

2.  Press 

 to arm the system.  

 

There is an exit delay prior to the system being armed. During this delay time, a slow 

beeping is heard to indicate that the system is not armed yet and reminds you to vacate 

the protected area. 

The following writing lights up at the screen to indicate that the system is armed: 

 

 

Armed A – for Area A, and Armed B – for Area B. 
 

The indicators may go out few seconds after exit delay times out, depending on the installation 

setting. 

q

 

To disarm the system during the exit delay, press 

Quick Arm (When enabled at installation)  

q

 

Press 

 to arm the system. 

 

During exit delay time, a slow beeping is heard reminding you to vacate the protected area. 

Содержание OLED

Страница 1: ...ELECTRONIC ENGINEERING LTD OLED Keypad User s Guide December 2009...

Страница 2: ...that this product can not be compromised or circumvented that this product will prevent any person injury or property loss or damage by burglary robbery fire or otherwise or that this product will in...

Страница 3: ...Fire Alarm 12 GENERATE THREAT OR DURESS 12 SYSTEM MESSAGES 12 HOW TO READ TROUBLE MESSAGES AND EVENTS FROM MEMORY 12 SPECIAL INDICATIONS 13 HOW TO CONTROL OUTPUTS AND DEVICES 14 ENTERING THE USER PRO...

Страница 4: ...Contents ii Copying Text to another LCD or OLED Keypad 23 Exiting Local Edit Program Mode 23...

Страница 5: ...pad also collects and records events to be displayed afterward on request to overview system activities and to analyze system performance for diagnostics Function Keys These keys are used to arm the s...

Страница 6: ...tected area When disarming the system it indicates you have entered the protected entry zone Indicators q ARM READY RED GREEN q TROUBLE RED Summary of Functions The system s main functions are listed...

Страница 7: ...enter MENU and scroll down until the bypass option Option 1 At this case Button assigned to operate bypass default Option 2 MENU Initiate Panic C Activates emergency alert Initiate Medical C Activates...

Страница 8: ...button can be one of the following buttons default Another way to use Chime operation is to enter a MENU and scroll down until the Chime option Control C CONTROL C Device C Activates or deactivates o...

Страница 9: ...ore leaving premises you must arm the system Arming the alarm system turns on all detectors in the partition s being armed 1 Enter your code 2 Press to arm the system There is an exit delay prior to t...

Страница 10: ...rming the System 1 Enter your code 2 Press The A or B indicator goes off the system is now disarmed Stopping and Resetting Alarms 1 Enter your code 2 Press This stops the alarm at any time and also tu...

Страница 11: ...n to indicate that the system is armed in stay mode Stay Armed A for Area A and Stay Armed B for Area B Quick Stay q Press to arm the system During exit delay you can leave the premises If you wish to...

Страница 12: ...ing exit delay you can leave premises At the end of the procedure the following writing lights up at the screen to indicate that the system is armed Armed A for Area A and Armed B for Area B To disarm...

Страница 13: ...ode press or NOTE Disarming automatically un bypasses all zone Using Chime If enabled at Installation A Chime Day zone is a detector that can be part armed while you are at home but working in another...

Страница 14: ...ss event without arousing suspicion For details ask the installer System Messages When viewing the memory events at the keypad by pressing the MEMORY the first thing that is always displayed is the sy...

Страница 15: ...n then by pressing on the button below will show the current status of the control panel it will show open zones bypassed zones and any informative data of the control panel If on the main screen of t...

Страница 16: ...user codes If you request it your installer can provide you with access to the INSTALLER mode as well To get into CLIENT mode provided the system is NOT armed Press enter Master code and If you get a...

Страница 17: ...100 to add or change the code press Use the numeric keyboard to enter the new code The code can hold any combination of 1 to 6 digits Entering the new code deletes the old code Press to save your new...

Страница 18: ...IENT mode How to Answer an In Coming Call From time to time your installer may need to access the alarm from a remote PC to make changes to your programming and for security reasons they may have conf...

Страница 19: ...d receive a status message Area A alarm is Disarmed or whatever message is programmed by the installer While you are on line with the panel you can move between menu options by entering the code of th...

Страница 20: ...ry mode Customised Area Names the Area name is displayed when viewing arm disarm events in memory mode and Customised Output Names the Output name is displayed when viewing Output On Off events in mem...

Страница 21: ...of Panel Users Zones Areas and Outputs Use the following buttons to select a desired menu and press or Use the following buttons to select desired item Press or to enter the edit mode For example the...

Страница 22: ...e the following buttons to move the cursor To save the new name press or To cancel press To restore default names or use suggested names press and select a desired name NOTE Use the same method to edi...

Страница 23: ...example in order to make a button to operate bypass press it 3 times This method works for other control buttons To save the new setting press button Changing Language To change the language enter the...

Страница 24: ...LCD backlight level Press To reduce the Crow LCD backlight level Press Press or to save the settings Press to cancel settings Resetting All Text to Default To reset text to default scroll down the men...

Страница 25: ...t is possible to copy the edited Text from one LCD or OLED keypad to all other LCD or OLED keypads connected to the same panel To copy text to other keypads scroll down the menus until the following m...

Страница 26: ...Operating the Keypad 24 NOTE Everywhere when pressing button is allowed you can press the button as well...

Страница 27: ...25...