background image

 

Operating the Keypad 

 

 

17 

Please talk to your installer to find out if all or any of these options are available on your alarm. 

To perform any of the Command Control features you must first ring the phone number, which 

the panel is connected to.  The panel may be set up to answer after a specific number of rings or 

it can be set-up to use a fax defeat option.  Either way, when you ring the phone number and 

the panel answers the call, the first thing you hear over the phone is a two seconds burst of 
modem tone. After this tone stops you must enter the access code, which is associated with the 

Command menu option you wish to access.  Remember, the code you enter determines which 
menu option you access
.  If you miss the pause, the panel repeats the modem tone and then 

pauses again for 5 seconds looking for your access code.  This process is repeated four times 

before hanging up, if no valid code is received.  When entering codes or other information in 

Command Control the "#" key acts as a "Clear" button. 

When you have entered the required 4-digit access code the panel replies with the status 

message associated with the Command Control function you have accessed.  For example, let's 

say we have a code of “2045” to allow Arming & Disarming of Area A. Once the code “2045” has 

been received the panel checks the current status of Area A and replies with the pre-

programmed voice message relating to that status. For example, if Area A is armed, then the 
Armed message is sent, if Disarmed then the Disarmed message is sent. If only the DTMF board 

is fitted, the voice message is substituted with a long beep if Area A is armed and three short 

beeps if it is disarmed. 

Once the status message has informed you of the actual state, you can use the "*" key to toggle 

the option on & off or Arm and Disarm, e.g. in our example above, code “2045” accesses Area 

"A" arming or disarming.  

Assuming the status message we received was "Area A alarm is Armed" If we press the "*" key, 

Area "A" is Disarmed and we would receive a status message "Area A alarm is Disarmed" (or 

whatever message is programmed by the installer). 

While you are on-line with the panel you can move between menu options by entering the code 

of the option you want to control. Assuming there was a code of “4321” programmed to control 

outputs. After having used code “2045” to control the Arm/Disarm status of Area A we first press 

the “#” button to reset all previous entries. Then we can enter the digits “43215” (that is “4321” 

as the code to control outputs and “5” to select output #5). The current status of output #5 is 

given either by the voice message or the appropriate tone and then the status can be changed 

with the “*” button on the remote telephone. 

NOTE: 

For output control you must enter the 4 digit code, for example,  4321 followed by the 

output number you wish to control, in this case 5

At any stage, if you enter in an incorrect code you can press the “#” button on the remote 

telephone to clear all code entries and then start again. 
To turn on the optional Microphone (only available if the Voice Board is fitted) you must enter in 
the appropriate code followed by the “*” button. To turn the Microphone off you simply press the 

“*” button again. 

To end a Command Control session simply hangs up the phone.  The panel is monitoring the line 

at all times and 15 seconds after the last key press it automatically hangs up the line.  This 15-

second timer is active during the whole command control process so a period of 15 seconds 

without a key press causes the panel to hang-up.   

Using Local Command Control  

If a command control code for outputs is programmed and the output/s are allowed to be locally 

controlled from the keypad, then entering the 4 digit code at a keypad blanks the display and the 
zone LED’s now indicate the output status. For example, if output 1 is on zone 1 LED is on.  

Pressing the “1” button at the panel keypad, output 1 can be turned off provided it is allowed to 

be locally controlled. To leave local command control mode simply press the 

 button and the 

keypad returns to normal operation. This feature works the same way that “Directly Controlling 

an Output” works only it requires a code to access the function. 

 

Содержание OLED

Страница 1: ...ELECTRONIC ENGINEERING LTD OLED Keypad User s Guide December 2009...

Страница 2: ...that this product can not be compromised or circumvented that this product will prevent any person injury or property loss or damage by burglary robbery fire or otherwise or that this product will in...

Страница 3: ...Fire Alarm 12 GENERATE THREAT OR DURESS 12 SYSTEM MESSAGES 12 HOW TO READ TROUBLE MESSAGES AND EVENTS FROM MEMORY 12 SPECIAL INDICATIONS 13 HOW TO CONTROL OUTPUTS AND DEVICES 14 ENTERING THE USER PRO...

Страница 4: ...Contents ii Copying Text to another LCD or OLED Keypad 23 Exiting Local Edit Program Mode 23...

Страница 5: ...pad also collects and records events to be displayed afterward on request to overview system activities and to analyze system performance for diagnostics Function Keys These keys are used to arm the s...

Страница 6: ...tected area When disarming the system it indicates you have entered the protected entry zone Indicators q ARM READY RED GREEN q TROUBLE RED Summary of Functions The system s main functions are listed...

Страница 7: ...enter MENU and scroll down until the bypass option Option 1 At this case Button assigned to operate bypass default Option 2 MENU Initiate Panic C Activates emergency alert Initiate Medical C Activates...

Страница 8: ...button can be one of the following buttons default Another way to use Chime operation is to enter a MENU and scroll down until the Chime option Control C CONTROL C Device C Activates or deactivates o...

Страница 9: ...ore leaving premises you must arm the system Arming the alarm system turns on all detectors in the partition s being armed 1 Enter your code 2 Press to arm the system There is an exit delay prior to t...

Страница 10: ...rming the System 1 Enter your code 2 Press The A or B indicator goes off the system is now disarmed Stopping and Resetting Alarms 1 Enter your code 2 Press This stops the alarm at any time and also tu...

Страница 11: ...n to indicate that the system is armed in stay mode Stay Armed A for Area A and Stay Armed B for Area B Quick Stay q Press to arm the system During exit delay you can leave the premises If you wish to...

Страница 12: ...ing exit delay you can leave premises At the end of the procedure the following writing lights up at the screen to indicate that the system is armed Armed A for Area A and Armed B for Area B To disarm...

Страница 13: ...ode press or NOTE Disarming automatically un bypasses all zone Using Chime If enabled at Installation A Chime Day zone is a detector that can be part armed while you are at home but working in another...

Страница 14: ...ss event without arousing suspicion For details ask the installer System Messages When viewing the memory events at the keypad by pressing the MEMORY the first thing that is always displayed is the sy...

Страница 15: ...n then by pressing on the button below will show the current status of the control panel it will show open zones bypassed zones and any informative data of the control panel If on the main screen of t...

Страница 16: ...user codes If you request it your installer can provide you with access to the INSTALLER mode as well To get into CLIENT mode provided the system is NOT armed Press enter Master code and If you get a...

Страница 17: ...100 to add or change the code press Use the numeric keyboard to enter the new code The code can hold any combination of 1 to 6 digits Entering the new code deletes the old code Press to save your new...

Страница 18: ...IENT mode How to Answer an In Coming Call From time to time your installer may need to access the alarm from a remote PC to make changes to your programming and for security reasons they may have conf...

Страница 19: ...d receive a status message Area A alarm is Disarmed or whatever message is programmed by the installer While you are on line with the panel you can move between menu options by entering the code of th...

Страница 20: ...ry mode Customised Area Names the Area name is displayed when viewing arm disarm events in memory mode and Customised Output Names the Output name is displayed when viewing Output On Off events in mem...

Страница 21: ...of Panel Users Zones Areas and Outputs Use the following buttons to select a desired menu and press or Use the following buttons to select desired item Press or to enter the edit mode For example the...

Страница 22: ...e the following buttons to move the cursor To save the new name press or To cancel press To restore default names or use suggested names press and select a desired name NOTE Use the same method to edi...

Страница 23: ...example in order to make a button to operate bypass press it 3 times This method works for other control buttons To save the new setting press button Changing Language To change the language enter the...

Страница 24: ...LCD backlight level Press To reduce the Crow LCD backlight level Press Press or to save the settings Press to cancel settings Resetting All Text to Default To reset text to default scroll down the men...

Страница 25: ...t is possible to copy the edited Text from one LCD or OLED keypad to all other LCD or OLED keypads connected to the same panel To copy text to other keypads scroll down the menus until the following m...

Страница 26: ...Operating the Keypad 24 NOTE Everywhere when pressing button is allowed you can press the button as well...

Страница 27: ...25...

Отзывы: