Installer Options
P25E
11E
Installer Options
(Default = All Off)
1 = Installer MUST enter program mode via Client mode to reset confirmed alarms
2 = Installer MUST enter program mode via Client mode to reset tamper alarms
3 = Installer MUST enter program mode via Client mode to reset low battery alarms
4 = Installer MUST enter program mode via Client mode to reset supervisory alarms
5 = Cannot Arm if there is a keypad Fault
6 = Cannot Arm if there is a Telephone Line Failure or Comms Fault
7 = 10 Incorrect Code Attempts locks out the keypad for 90 Seconds
8 = User Codes Must be 4-6 digits long
User Options
P25E
12E
User Options (NOTE: This Option can ONLY be accessed from Client Mode)
(Default = All Off)
1 = Hide User Codes from Installer
P25E
13E
Misc. User Options
Miscellaneous User Options
(Default = None)
1 = Code Required to View Memory
2 = Cancel Handover Zone Function in Stay Mode
3 = Output Control from Keypad is Disabled when Armed
4 = Keypad Codes are Disabled During Entry Delay
5 = Keypad LED’s and Backlight off on no activity
6 = Use new multi-area arming method
7 = Enable Keypad Tamper Switch Alarms
8 = Spare
LCD KP “Idle” Display Name
P25E
14E
This location is where the LCD KP “Idle” Display Name can be Programmed.
Webpage “Incorrect Login” Count
P25E
15E
0-255. If this address is set to 0 there is no incorrect login count. If set from 1-255, that is
the number of incorrect login attempts before the webpage access is locked out.
Webpage “Incorrect Login” Lockout Time
P25E
16E
0-9999. If this address is set to 0 there is no lockout time if the programmed count at
P25E15E is exceeded. If set from 1-9999, that is the time in seconds that all webpage
access will be locked out for.
World Time Zone
P25E
17E
World Time Zone
Program Mode/Arming Options
P25E
18E
Prog/Arm Options
Program Mode/Arming Options
(Default = None)
1 = Can enter program mode when another area is armed
2 = Can arm when a keypad in a different area is in program mode
3 = Serial over IP Authentication Required
8 = Hide extended information in the memory events
Serial over IP User Name
P25E
19E
Serial over IP User Name
(maximum 16 characters)
Serial over IP Password
P25E
20E
Serial over IP Password
(maximum 16 characters)
Serial over IP User Timeout
P25E
21E
Serial over IP User Timeout
(Default = 300, 10-600 seconds)
Setting Real Time Clock
P26E
1E
Real Time Hour/Minute -
Value 0-2359
P26E
2E
Real Time Day of Week -
Value 1-7 (1=Sunday, 2=Monday ,etc)
P26E
3E
Real Time Date/Month/Year -
Value DDMMYY (eg 020904 = 2nd Sept 2004)
P26E
4E
Daylight Saving is Active
(If LED #1 is On, Daylight Saving is currently active) Turn this bit ON if you are in
Daylight Saving Time when the panel is installed.
NOTE: If option 3 at P201E4E is turned on (panel clock synced to the internet time) the
above time and date settings cannot be altered.
Daylight Saving settings
P27E
1E
Daylight Saving Start Sunday -
Value 0-5 - Default = 5 (0 = DLS disabled, 5 = last Sunday of Month)
2E
Daylight Saving End Sunday -
Value 0-5 - Default = 1 (0 = DLS disabled, 5 = last Sunday of Month)
P28E
1E
Daylight Saving Start Month -
Value 1-12 - Default = 9
2E
Daylight Saving End Month -
Value 1-12 - Default = 4
P29E
1E
Daylight Saving Start Hour -
Value 0-23 - Default = 2
2E
Daylight Saving End Hour -
Value 0-23 - Default = 3