Page 14
“A”+”B” Fire Alarm to Outputs
P85E
1-32E
Keypad “A”+”B” Fire Alarm to Outputs
(Default = 1,2)
01-32 = The Keypad “A”+”B” Fire Alarm will turn on Output # 1-32
“B”+”Chime” Medical Alarm to Outputs
P86E
1-32E
Keypad “B”+”Chime” Medical Alarm to Outputs
(Default = 1,2)
01-32 = The Keypad “B”+”Chime” Medical Alarm will turn on Output # 1-32
“Duress” Alarm to Outputs
P87E
1-32E
Keypad “Duress” Alarm to Outputs
(Default = All Off)
01-32 = The Keypad “Duress” Alarm will turn on Output # 1-32
Keypad “Tamper Switch” Alarm to Outputs
P88E
1-32E
Keypad “Tamper Switch” Alarm to Outputs
(Default = All Off)
01-32 = The Keypad “Tamper Switch” Alarm will turn on Output # 1-32
Keypad “Wrong Code” Alarm to Outputs
P89E
1-32E
Keypad “Wrong Code” Alarm to Outputs
(Default = All Off)
01-32 = The Keypad “Wrong Code” Alarm will turn on Output # 1-32
Manually Operated Panic Alarm Beeps to Keypads
P90E
1-32E
Panic Alarm Beeps to Keypads
(Default = All On)
01-32 = A Panic Alarm at the selected keypad will Beep KP # 1-32
Manually Operated Fire Alarm Beeps to Keypads
P91E
1-32E
Fire Alarm Beeps to Keypads
(Default = All On)
01-32 = A Fire Alarm at the selected keypad will Beep KP # 1-32
Manually Operated Medical Alarm Beeps to Keypads
P92E
1-32E
Medical Alarm Beeps to Keypads
(Default = All On)
01-32 = A Medical Alarm at the selected keypad will Beep KP # 1-32
Wrong Code or Keypad Tamper Switch Alarm Beeps to Keypads
P93E
1-32E
Wrong Code or Keypad Tamper Switch Alarm Beeps to Keypads
(Default = All On)
01-32 = Wrong Code or KP Tamper at Keypad 1-32 will Beep KP # 1-32
Chime Alarm Beep Time at a Keypad
P94E
1-32E
The Time the Chime Alarm will sound at Each Keypad
-
Value =0-255 1/10th sec
(Default = 20 which is 2 Seconds)
LCD Keypad Back-light settings
P95E
1-32E
LCD Keypad Back-light Setting
0-100 = LCD B/L value 0-100%
Full LCD Keypad Display Options
P96E
1-32E
Full LCD Keypad Display Options
1 = 2 x 20 Display Mode (On=AAP Logo Display)
(Default = All Off)
2 = Spare
3 = Show LCD System name (ON=Show KP Name, 1 =OFF)
4 = Display Armed Areas as numbers
5 = Spare
6 = Allow CONTROL of Outputs when Armed
7 = Double badge to ARM keypad
8 = Control button operates assigned outputs directly
Bulk COPY a Keypad to a range of Keypads
P97E
Template KP #E Start KP #E End KP #E Bulk COPY a Keypad to a range of KEYPADS
Proximity Reader LED to Output Mapping
P98E
1-32E
Proximity Reader LED to Output Mapping
(Default = None)
01-32 = Proximity Reader 1-32 LED will follow the state of Output # 1-32
Program LCD KP “Keypad” Name
P100E 1-32E
Program LCD KP “Keypad” Name Text
+++++Zones+++++
Bulk COPY a Zone to a range of Zones
P118E Template Zone #E Start Zone #E End Zone #E Bulk COPY a Zone to a range of ZONES
Global EOL Zone Options
P119E 1E
Global EOL Zone Options
0 = If set to 0 allows P125E to set individual values from 1-13
(Default = 3)
1 = 1k
2 = 1k5
3 = 2k2
4 = 3k3
5 = 3k9
6 = 4k7
7 = 5k6