Page 5
DISPLAY IP & MAC ADDRESS AT THE KEYPAD
When the panel is in normal mode (ie not in program mode) it is possible to display the currently assigned IP address
for the panel and the MAC address. This feature is only available at the full LCD Keypad, it is not available on the
ICON LCD keypad.
To view the MAC Address
At the LCD keypad press and hold the <8> button for 4 seconds until the display shows the panels MAC address. To
exit the display mode press the <ENTER> button.
To view the IP Address
At the LCD keypad press and hold the <9> button for 4 seconds until the display shows the panels IP address. To
exit the display mode press the <ENTER> button.
Automatic Control of Doors
When there is a need to unlock a controlled door during the day and keep it unlocked, this can be achieved two
ways. The first is to program a Time Zone to the output (P44E), the second is to program the area disarm indication
to the output (P49E).
Unlock on a Time Zone
Any of the 32 Time-zones can be assigned to outputs 1-32. This function can be used to unlock a controlled door so
the door will remain unlocked while the T/Z is on and relock it when the T/Z is off allowing normal timed access con-
trol through the door when the T/Z is inactive. If a TZ has turned an Output ON the TZ will override any reset time
programmed for the Output. A TZ can be linked to holidays (P174E option 1 Off) so that the TZ will not unlock the
door when a holiday is active. The reset, pulse or chime timers can resume controlling the Output once the TZ has
ended and the output is OFF. The CONTROL to Output function is the only operation that can override the Output
while the TZ is active (see additional comment below).
Unlock when Disarmed
Each Area can have a disarm indication assigned to an output to unlock a controlled door so the door will remain
unlocked while the alarm is disarmed and relock it when the alarm is armed allowing normal timed access control
through the door afterhours. This function allows a door to be unlocked only when the premises are occupied and
relocked when the premises are vacated (ie the alarm is armed). If an Area Disarm has turned an Output ON this will
override any reset time programmed for the Output. The reset, pulse or chime timers can resume controlling the Out-
put once the Area is armed and the output is OFF. The CONTROL to Output function is the only operation that can
override the Output while disarmed (see additional comment below).
<CONTROL> override of an unlocked door
When an output is on because a TZ is active or the alarm is disarmed the output will stay on until the TZ is inactive or
the alarm is armed.
At times there may be reasons why the door needs to be locked even if a TZ is active or the alarm is disarmed, (eg
an employee is at work on a public holiday and the alarm is disarmed but they want the door to be locked).
Under these special conditions it is possible to program the output connected to the door so that it can be controlled
using the <CONTROL> button at the keypad closest to the controlled door. At Program address P83E the output
controlling the door can be assigned to a keypad close to the controlled door. By pressing the control button for 2
seconds (option 8 must be on at P96E to allow direct control of the output) the door control can be overridden. If the
control button is pressed for another 2 seconds it will unlock the door again.