3.7 Max. time to wait until „0“ is displayed
This parameter indicates, how long it takes,
when measuring is active, until „0“ is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
3.8 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and modi-
fied.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.
Time meter
(Operating mode time meter)
1. Description
• 6 digit time meter with SET/RESET function
• Red LED display, character height 8 mm
• Display range from 0 to 999 999
• Leading zeros suppression.
• Operation indicator: the decimal point of the
lowest digit blinks while the count is active.
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Time meter operating modes
– Counting while INP B is inactive (GAtE.Lo)
– Counting while INP B is active (GatE.hi)
– Count Start/Stop with INP B edge (Inb.Inb)
– Count Start with INP A edge, count Stop
with INP B edge (InA.Inb)
• Counting ranges h; min; s; h.min.s
2. Inputs
INP A
Start input (depending on the input mode chosen)
INP B
Start/Stop or gate input (depending on the input
mode chosen)
SET/RESET input
Dynamic SET/RESET input. Linked in parallel to
the red RESET key. Resets the counter to the pre-
defined setting value.
3. Programming routine
The programmable parameters of the device are
described below, in the order in which they can be
set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings