Quadrature input
INP A: count input 0°
INP B: count input 90°
Quadrature input with
pulse doubling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
will be counted
Quadrature input with
pulse quadrupling
INP A: count input 0°
INP B: count input 90°
Each pulse edge of INP A
and INP B will be count-
ed.
3.4 Input mode
3.5 Multiplying factor
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0“ is not accepted!
3.8 SET/RESET Mode
manual reset via the red
SET/RESET key and
electrical reset via the
SET/RESET input
no reset (red SET/RESET
key and SET/RESET
input locked)
only electrical reset via
the SET/RESET input
only manual reset via
the red SET/RESET key
3.7 Decimal point
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0 no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0“ is not accepted!
3.6 Dividing factor
3.9 SET value
The device will be set to
the set point by pressing
the red SET/RESET key
or activating the
SET/RESET input.
SET value -199999...
999999 (number of deci-
mal places depends on
the decimal point option)
For programming the decimal point see 4.6
3.10 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and modi-
fied.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.