CCpilot VS 12”
Product revision: A
Technical Manual
2017-11-23
www.crosscontrol.com
27
Electrical Transients
ISO 7637-2:2011
12 V system
24 V system
Pulse
Level
1
-25V
2
+25V
3a
-25V
3b
+25V
4
-4V
5
+26,5V, Ri = 2Ω
1
-450V
2a
+37V
2b
+20V
3a
-150V
3b
+150V
4
-12V
5
+123V, Ri = 2Ω
ESD immunity
ISO 10605:2008, EN 61000-4-2
Air
± 8 kV
Contact
± 6 kV
Radiated RF immunity
(1)
ISO 11452-2:2004
MHz
Level
Modulation
200-2000
30 V/m 80%AM, 1kHz
Induces RF immunity
(1)
ISO 11452-4:2005/Cor.1:2009
(BCI)
MHz
Level
Modulation
20-200 60 mA 80%AM, 1kHz
Radiated RF emission
(1)
ISO 13309:2010
Narrow-b. Broad-b.
MHz
dBµV/m
dBµV/m
30-75
54-44
64-54
75-400
44-55
54-65
400-1000
55
65
(1) Compliance to RF immunity and RF emission standards require use of shielded cables for Ethernet, USB and Video interfaces.
EMC tests are performed at 24 V
DC
supply voltage unless other levels are specified in test standards.
System level compliance to EMC standards may be affected by external factors like mounting,
omitting the use of shielded cables etc.
7.4.
Weight and dimensions
Attribute
Description
Comments
Dimensions
312 x 213 x 66 mm
(W x H x D)
Weight
2.0 kg
Mounting holes
Spacing
Thread dimension
Thread depth
VESA75
75 mm
M5
8 mm
Enclosure material
Glass fiber reinforced
polyamide