CCpilot VS 12”
Product revision: A
Technical Manual
2017-11-23
www.crosscontrol.com
23
Typical, operating
Max, operating
Device without ext loads
4x USB @ max load
6x HS out @ max load
Shutdown
Vin = 12 V
DC
Vin = 24 V
DC
17 W (typ)
17 W (typ)
143 W max
230 W max
17 W max
17 W max
40 W max
40 W max
86 W max
173 W max
0.44 mA
(typ)
0.85 mA (typ)
Inrush current
Duration ca 60 ms
Vin = 12 V
DC
Vin = 24 V
DC
< 8.5 A
< 4.5 A
External fuse recommendation
Current rating
15 A*
(including maximum external loads)
* This assumes that the fuse is in accordance with IEC 20127 i.e. can be continuously
operated at 100% of rated current.
CAN interfaces
Type
Non-isolated, ISO 11898-2, CAN 2.0B with cable shield decoupling
according to J1939-11.
Supports ISOBUS
CAN transceiver
NXP TJA1051T/3
Baud Rate
20 – 250 kbps (up to 1 Mbps)*
* Internal CAN bus filters have a capacitance of 100pF (typ) as stated in the J1939 specification. This
puts restrictions on the CAN bus topology considering bus length, number of CAN nodes etc. when
running at bit-rates higher than 250 kbps.
Protection
Short circuit protected to -32V to +32V
USB interfaces
Type
4x USB 2.0 compatible host ports
Two USB ports are available in M12 connectors, the remaining ports are USB type A connectors covered
by a removable rubber sealing. Device IP-classification is not retained when the USB sealing is removed.
Speed
Full-speed (12 Mbps) and Hi-speed USB (480 Mbps) is supported.
VBUS supply
According to USB specification, but with increased drive capacity
5.0 V, 2 A per port, internally over-current and short-circuit protected.
Ethernet
Type
Gigabit Ethernet compatible with 10BASE-T, 100BASE-TX and
1000Base-T Ethernet standards.
Auto-MDIX support.
Insulation voltage
1000 V
AC
, 50/60Hz for 1 minute.
Analog video
Number of inputs
1