High-side digital outputs
Number of channels
6
Current limit
Initial peak current
Repetitive short-circuit
1200 mA (typ) (min 700 mA, max 2000 mA) per channel
1000 mA (typ)
.
Diagnostics
OFF state diagnostics
ON state diagnostics
Built-on diagnostics and fault flag monitoring.
To ensure long-term reliability, the fault flags are continuously monitored and each output is
automatically switched OFF in case the fault flag is triggered in ON state.
Open load, short to battery
Over-load (or short to GND), over-temperature
Open-load detection
Internal pull-up current
Threshold voltage
5 µA (typ)
2.0 V (typ) (min 1.5V, max 3.5V)
Open load is detected when output voltage rises above the threshold voltage in OFF state.
Short-circuit detection
Voltage threshold
2.8 V (typ)
Over-current is detected when output voltage falls below the threshold voltage in ON state.
Over-temp. detection
Turn-off Threshold
Hysteresis
+175 °C typ (min 150 °C, max 200 °C)
10 °C
ON-state resistance
400 mΩ (typ), 700 mΩ (max)
Slew rate
Turn ON:
Turn OFF:
80 µs (typ), 180 µs (max)
80 µs (typ), 200 µs (max)
OFF-state leakage
5 µA (typ)
12 µA (max)
Buzzer
Frequency range
1 – 20 kHz (SPL peak at 3200 Hz)
SPL
85 dBA at 1 meter (typ, 3200 Hz)
The buzzer is located on the back (connector side) of the device and the effective SPL varies
dependent on the acoustic properties of the installation environment.
Button and Status notification
On/off button
On/off button with backlight and tactile feedback.
Status notification
Button backlight is used for status notification, such as blinking at 2 Hz
during start-up, etc.
Software
Operating system
Yocto Linux, Kernel version 4.1.38
Additional software
CCAux API. Refer to the
CCpilot VS Software Guide
and
P
rogrammer
’
s guide