2.3 M&C Queries
x = 3 if Auto 10 MHz reference is selected
x = 2 if External 10 MHz reference is selected
x = 1 if Internal 10 MHz reference is selected
Returns {aaSEx} where:
{aaSE}
10 MHz reference
Example: {aaSG+090} indicates that the current gain
setting is +9.0 dB
Range: (+20 to 0 in 1 dB steps)
xxxx = 4 characters
Returns {aaSGxxxx} where:
{aaSG}
Gain
x = 11 if band 11 is selected: in = (30.0 to 31.0 GHz)
x = 1 if band 1 is selected: in = (27.5 to 28.5 GHz)
x = 10 if band 10 is selected: in = (28.0 to 29.0 GHz)
x = 9 if band 9 is selected: in = (29.0 to 30.0 GHz)
x = 8 if band 8 is selected: in = (28.0 to 29.0 GHz)
x = 7 if band 7 is selected: in = (28.0 to 29.0 GHz)
x = 6 if band 6 is selected: in = (27.5 to 28.5 GHz)
x = 5 if band 5 is selected: in = (27.5 to 28.5 GHz)
x = 4 if band 4 is selected: in = (30.0 to 31.0 GHz)
x = 3 if band 3 is selected: in = (29.0 to 30.0 GHz)
x = 2 if band 2 is selected: in = (28.0 to 29.0 GHz)
Returns {aaSBx} where:
{aaSB}
Frequency Band
Description
Syntax
Queries
Table 2.1: Model 4116-T300 M&C Queries
continued on page 10...
4116-T300 Manual_F
Page 9
11/05/15