2.4  ETHERNET Interface Installation and Operation

The 4116-T300 Ka-Band Translator is equipped with a 10/100 Base-T compatible Ethernet interface for control 

and monitoring of its operating parameters.  An HTML script interface allows the user to monitor and control 

the converter using a standard web browser.  SNMP (Simple Network Management Protocol) is also supported.  

Contact Cross Technologies for the SNMP MIB file.  

2.4.1  Methods of Connection

Directly Connected to a PC:

For control from a local PC, attach the 4116-T300’s Ethernet port to the Ethernet network connector on the 

PC using a crossover RJ-45 cable.  

LAN Connection 

For LAN connections, attach the 4116-T300’s Ethernet port to the LAN using a normal RJ-45 cable.  

Use any PC on the LAN to connect to the 4116-T300.

2.4.2  Ethernet Configuration

Each 4116-T300 must be configured with an appropriate IP address, Netmask, and Gateway assigned by your 
network manager.  The 4116-T300 is set at the factory to the static address 192.168.123.2.  The device server in 
the 4116-T300 has a built in HTTP based configuration manager that is used to configure network settings.  To 
access the configuration manager open a web browser and enter the IP address of the 4116-T300 in the 
browser's address field.   The window shown in Figure 2-A will appear.  As delivered, there is no password set.  
Choose your user name and password here or leave those fields blank and click OK to proceed to the 
configuration manager webpage.

Figure 2-A:  Password Screen

4116-T300 Manual_F  

               Page 12

  

                                 11/05/15

Содержание 4116-T300

Страница 1: ...ed without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipmen...

Страница 2: ...t defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s...

Страница 3: ...Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are d...

Страница 4: ...nd 9 8 800 8 3 9 8 19 2 20 2 28 0 29 0 Band 8 10 300 9 3 10 3 17 7 18 7 28 0 29 0 Band 7 8 300 8 3 9 3 19 2 20 2 27 5 28 5 Band 6 9 200 8 3 10 2 18 3 19 3 27 5 28 5 Band 5 9 800 8 8 10 3 20 2 21 2 30...

Страница 5: ...1 1 dB steps Gain at Fc 105 93 77 75 65 1M 100K 10K 1K 100 dBC Hz Phase Noise Frequency Hz Gain Band select and internal 10MHz frequency via Ethernet M C or Status Control connector Gain Band 10M Fre...

Страница 6: ...Crimp Pins and CL and CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts max 2 Neutral 3 Ground 2 1 Message Protocol The serial format for the RS232 RS422 RS485...

Страница 7: ...steps if Band 1 is selected Range 500 to 1000 in 5 MHz steps yyyyy Translation Frequency Offset xx Band Range 1 to 11 where aaCxx yyyy Set Frequency Offset x 11 to select band 11 in 30 0 to 31 0 GHz O...

Страница 8: ...eference x 1 to mute the output x 0 to unmute the output xx 2 characters where aaCEx Set 10 MHz reference mode Range 2000 to 2000 xxxxx 5 characters where aaCOxxxxx Set Int 10 MHz reference offset Ran...

Страница 9: ...ected in 27 5 to 28 5 GHz x 10 if band 10 is selected in 28 0 to 29 0 GHz x 9 if band 9 is selected in 29 0 to 30 0 GHz x 8 if band 8 is selected in 28 0 to 29 0 GHz x 7 if band 7 is selected in 28 0...

Страница 10: ...if Band 8 is selected Range 1000 to 500 in 5 MHz steps if Band 7 is selected Range 0 to 1000 in 5 MHz steps if Band 6 is selected Range 1000 to 0 in 5 MHz steps if Band 5 is selected Range 1000 to 900...

Страница 11: ...ry alarm x 1 if summary alarm aaSA Unit Status Returns aaSTxxx where y 0 if unit is using internal 10 MHz ref y 1 if unit is using external reference Returns aaSAxy where Range 2000 to 2000 xxxxx 5 ch...

Страница 12: ...16 T300 s Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4116 T300 2 4 2 Ethernet Configuration Each 4116 T300 must be configured with an appropriate IP ad...

Страница 13: ...k and Gateway address with delimiter dots example 192 168 192 47 2 4 3 Webpage M C Enter the following address in a web browser to access the M C webpage http ip address of 41xx serial 0 setup htm whe...

Страница 14: ...using Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock...

Страница 15: ...r SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses o...

Страница 16: ...Figure 2 F Device Server Configuration Menu 4116 T300 Manual_F Page 16 11 05 15...

Страница 17: ...19 2 to 20 2 Band 9 18 7 to 19 7 Band 10 19 0 to 20 0 Band 11 20 0 to 21 0 10MHz OUTPUT SMA female 50 output level input level 1 dB 10MHz INPUT SMA female 50 Insert External 10MHz Reference here 2 to...

Страница 18: ...itor and Control Connector Table Table 2 6 1 Monitor and Control Connector Pinouts Conne Connector part number MS3112E14 18S Mating Mating Cable Connector part number MS3116F14 18P Pin Signal Descript...

Страница 19: ...T for external 10 MHz 2 to 8 dBm reference that is inserted at J2 via Ethernet or serial command see Section 2 0 and Table 2 6 1 8 Check that a 10 MHz signal is present at the 10 MHz REF OUTPUT at the...

Страница 20: ...ES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4116 T300 Manual_F...

Отзывы: