2.0  Installation

The 4116-T300 Ka-Band Translator consists of a 

8” Wide X 6” High X 16” Deep  Weather Resistant* 

enclosure

.  A switching, ±12, +24, +5 VDC power supply provides power for the internal assemblies. The 

4116-T300 can be secured to a mounting plate using the 4 holes on the bottom of the front and rear panels.  
(See Figure 2.5 for mounting dimensions.)

Figure 2  -  4116-T300 Ka-Band Translator Front Panel

2.0.1 Connection to AC Input Power

The 4116-T300 is furnished with a pre-assembled AC power input cable as described below.

4116-T3

4116-T310 Power Input Connector, FCI Clipper Series, CL1M1102 & Crimp Pins

Mating 

Mating Connector Clipper Series, CL1F1101 Crimp Pins

and CL

and CL101021 Backshell

Pin   Input  Connector  Pin  Description

1

 100-240 ±10% VAC, 47-63 Hz, 20 watts max.

2

 Neutral

3

 Ground

2.1 Message Protocol

The serial format for the RS232/RS422/RS485 port is 9600 baud, 8 data bits, no parity, and 1 stop bit.  All 
messages consist of ASCII printable characters so standard terminals and terminal emulator programs may be 
used to control and monitor the unit.  All messages begin with the open bracket character “

{

 

(ASCII 0x7B) and 

end with the close bracket character “

}

” (ASCII 0x7D).  Messages consisting of commands to set or change 

operating parameters and modes of the unit begin with “C” (ascii 0x43) followed by a command specific 
character.  Messages consisting of queries to report operating parameters and modes begin with “S”
(ASCII 0x53) followed by a parameter specific character.  

4116-T300 Manual_F  

               Page 6

  

                                 11/05/15

Содержание 4116-T300

Страница 1: ...ed without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipmen...

Страница 2: ...t defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s...

Страница 3: ...Resistant enclosures are designed to be water resistant for installation in an outdoor enclosure antenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are d...

Страница 4: ...nd 9 8 800 8 3 9 8 19 2 20 2 28 0 29 0 Band 8 10 300 9 3 10 3 17 7 18 7 28 0 29 0 Band 7 8 300 8 3 9 3 19 2 20 2 27 5 28 5 Band 6 9 200 8 3 10 2 18 3 19 3 27 5 28 5 Band 5 9 800 8 8 10 3 20 2 21 2 30...

Страница 5: ...1 1 dB steps Gain at Fc 105 93 77 75 65 1M 100K 10K 1K 100 dBC Hz Phase Noise Frequency Hz Gain Band select and internal 10MHz frequency via Ethernet M C or Status Control connector Gain Band 10M Fre...

Страница 6: ...Crimp Pins and CL and CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts max 2 Neutral 3 Ground 2 1 Message Protocol The serial format for the RS232 RS422 RS485...

Страница 7: ...steps if Band 1 is selected Range 500 to 1000 in 5 MHz steps yyyyy Translation Frequency Offset xx Band Range 1 to 11 where aaCxx yyyy Set Frequency Offset x 11 to select band 11 in 30 0 to 31 0 GHz O...

Страница 8: ...eference x 1 to mute the output x 0 to unmute the output xx 2 characters where aaCEx Set 10 MHz reference mode Range 2000 to 2000 xxxxx 5 characters where aaCOxxxxx Set Int 10 MHz reference offset Ran...

Страница 9: ...ected in 27 5 to 28 5 GHz x 10 if band 10 is selected in 28 0 to 29 0 GHz x 9 if band 9 is selected in 29 0 to 30 0 GHz x 8 if band 8 is selected in 28 0 to 29 0 GHz x 7 if band 7 is selected in 28 0...

Страница 10: ...if Band 8 is selected Range 1000 to 500 in 5 MHz steps if Band 7 is selected Range 0 to 1000 in 5 MHz steps if Band 6 is selected Range 1000 to 0 in 5 MHz steps if Band 5 is selected Range 1000 to 900...

Страница 11: ...ry alarm x 1 if summary alarm aaSA Unit Status Returns aaSTxxx where y 0 if unit is using internal 10 MHz ref y 1 if unit is using external reference Returns aaSAxy where Range 2000 to 2000 xxxxx 5 ch...

Страница 12: ...16 T300 s Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4116 T300 2 4 2 Ethernet Configuration Each 4116 T300 must be configured with an appropriate IP ad...

Страница 13: ...k and Gateway address with delimiter dots example 192 168 192 47 2 4 3 Webpage M C Enter the following address in a web browser to access the M C webpage http ip address of 41xx serial 0 setup htm whe...

Страница 14: ...using Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock...

Страница 15: ...r SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses o...

Страница 16: ...Figure 2 F Device Server Configuration Menu 4116 T300 Manual_F Page 16 11 05 15...

Страница 17: ...19 2 to 20 2 Band 9 18 7 to 19 7 Band 10 19 0 to 20 0 Band 11 20 0 to 21 0 10MHz OUTPUT SMA female 50 output level input level 1 dB 10MHz INPUT SMA female 50 Insert External 10MHz Reference here 2 to...

Страница 18: ...itor and Control Connector Table Table 2 6 1 Monitor and Control Connector Pinouts Conne Connector part number MS3112E14 18S Mating Mating Cable Connector part number MS3116F14 18P Pin Signal Descript...

Страница 19: ...T for external 10 MHz 2 to 8 dBm reference that is inserted at J2 via Ethernet or serial command see Section 2 0 and Table 2 6 1 8 Check that a 10 MHz signal is present at the 10 MHz REF OUTPUT at the...

Страница 20: ...ES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4116 T300 Manual_F...

Отзывы: