background image

1.2   Technical Characteristics

Technical Characteristics continued on page 5...

4115-300 Manual, Rev. H

 

                      Page 4   

                                 11/16/15

 ±2 dB, over RF band; ± 0.5 dB, 40 MHz BW, Frequency Sense-Non-Inverting

   Frequency Response

 Channel Characteristics

 LO Characteristics

 ± 0.05 ppm maximum over temp internal reference; external reference input

   Frequency Accuracy

 < -45 dBC for two carriers at 4 MHz spacing, each at -5 dBm out

   Intermodulation

 <-50 dBm, over 27.0 - 27.5 and 31.0 - 31.5 GHz Band

   Spurious, Out of Band

 

SIGNAL RELATED <-50 dBC in band, -15 to 0 dBm out; 

 SIGNAL INDEPENDENT, <-55 dBm; over 27.5 to 31 GHz Band

   Spurious, Inband

 +2 to +8 dBm in, Monitor Output = input level ± 1.0 dB, 50 ohms

   10 MHz Level In/Mon

 Band Specific

   LO Frequency

 + 30 ± 3 dB, (+30 to 0 dB variable in 0.5 dB Steps)

   Gain @ Fc

           -105

           -95

            -80

           -75

         -65

           1MHz

         100kHz

          10kHz

          1kHz

     100 MHz 

                              dBC/Hz

   Phase Noise @ F (Hz) >

 Controls, Indicators

 Green LED

   Power

 Gain, band select and internal 10 MHz frequency via Ethernet, 
 M&C or Status/Control Connector

  Gain, Band, 10M Frequency

 Red LED, External Contact Closure

   PLL, Alarm

 TABLE 1.0

4115-300 Block Upconverter Specifications**

 Band 4 - 30.0 to 31.0

 +8 dBm, maximum gain

  Output 1 dB Compression

 Band 3 - 29.0 to 30.0

 Band 2 - 28.0 to 29.0

 -40 to -15 dBm

  Input Level

 20 dB maximum gain

  Noise Figure, Maximum

 0.95 to 1.95 GHz

  Frequency (GHz)

 >60 dB @ 0 dBm Output

  Mute at Maximum Level Out

 -15 to 0 dBm

  Output Level Range

 Output Characteristics 

 Input Characteristics

 Band 1 - 27.5 to 28.5

  Frequency (GHz)

 50

Ω

 / 14 dB, Mute & Unmute

  Impedance / Return Loss

 50

Ω

 / 14 dB

  Impedance / Return Loss

Содержание 4115-300

Страница 1: ...ed without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipmen...

Страница 2: ...tive materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option...

Страница 3: ...tenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be located out in the elements water sleet snow etc but they are not designed to be subm...

Страница 4: ...MHz Level In Mon Band Specific LO Frequency 30 3 dB 30 to 0 dB variable in 0 5 dB Steps Gain Fc 105 95 80 75 65 1MHz 100kHz 10kHz 1kHz 100 MHz dBC Hz Phase Noise F Hz Controls Indicators Green LED Po...

Страница 5: ...MS3112E14 18S Mating Cable Connector MS3116F14 18P Ethernet Conector RJF21B Mating Cable Connector RJF6G Cable interface Standard RJ45 AC Input Connector Clipper Series CL1M1102 Mating Cable Connector...

Страница 6: ...d CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts max 2 Neutral 3 Ground 2 1 Message Protocol The serial format for the RS232 RS422 RS485 port is 9600 baud 8...

Страница 7: ...ge 2000 to 8000 xxxxx 5 characters where aaCOxxxxx Set Int 10 MHz reference offset Range 0 to 31 xx 2 characters where aaCRxx Set RS485 address x 2 to select RS485 x 0 to select RS232 where aaCIx Set...

Страница 8: ...s selected Returns aaSIx where aaSI Serial Interface x 2 if External 10 MHz reference is selected x 1 if Internal 10 MHz reference is selected Returns aaSEx where aaSE 10 MHz reference Range 0 to 300...

Страница 9: ...to 99 degrees Celsius xxx 3 characters Returns aaSTxxx where aaST Internal Temperature y 0 if unit is using internal 10 MHz ref y 1 if unit is using external reference x 0 if no summary alarm x 1 if s...

Страница 10: ...115 300 Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4115 300 2 4 2 Ethernet Configuration Each 4115 300 must be configured with an appropriate IP addres...

Страница 11: ...delimiter dots example 192 168 192 47 Click on apply settings to apply the new settings in the device server 2 4 3 Web page M C Enter the following address in a web browser to access the M C web page...

Страница 12: ...ws XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock from the Con...

Страница 13: ...SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of...

Страница 14: ...Figure 2 F Device Server Configuration Menu 4115 300 Manual Rev H Page 14 11 16 15...

Страница 15: ...S CONTROL CONNECTOR Weatherized MS3112E14 18S 18 pin connector See Table 2 6 REF INPUT Type N female 50 0 95 to 1 95 dBm See Table 2 1 ETHERNET CONNECTOR Weatherized Standard RJ45 Ethernet Connector F...

Страница 16: ...tor and Control Connector Monito Monitor and Control Connector Pinout MS3112E14 18S Conne Connector part number MS3112E14 18S Mating Mating Connector part number MS3116F14 18P Pin Signal Description A...

Страница 17: ...J2 or EXT for external 10 MHz 2 to 8 dBm ref that is inserted at J2 on front panel switch S1 see Table 2 0 8 Check that a 10 MHz signal is present at the 10 MHz REF OUTPUT at the same level as the inp...

Страница 18: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4115 300 Manual Rev H...

Отзывы: