2.3 M&C Queries
Table 2.1 Model 4115-300 M&C Queries
x = if band 4 is selected in = (950 to 1950 MHz)
out = (30.0 to 31.0 MHz)
x = 1 if mute is on
x = 0 if mute is off
Returns {aaSMx} where:
{aaSM}
Mute
x = 1 if RS422 is selected
Example: {aaSG245} indicates the current
gain setting is 24.5 dB
Range: 00 to 31
x = 2 if RS485 is selected
x = 3 if Auto 10 MHz reference is selected
xx = 2 characters
Returns {aaSAxx} where:
{aaSR}
RS485 address
x = 0 if RS232 is selected
Returns {aaS
I
x} where:
{aaS
I
}
Serial Interface
x = 2 if External 10 MHz reference is selected
x = 1 if Internal 10 MHz reference is selected
Returns {aaSEx} where:
{aaSE}
10 MHz reference
Range: 0 to 300 ( in 0.5 dB steps)
xxx = 3 characters
Returns {aaSGxxx} where:
{aaSG}
Gain
x = if band 3 is selected in = (950 to 2050 MHz)
out = (29.0 to 30.0 MHz)
x = 2 if band 2 is selected in = (950 to 2050 MHz)
out = (28.0 to 29.0 MHz)
x = 1 if band 1 is selected in = (950 to 2050 MHz)
out = (27.5 to 28.5 MHz)
Returns {aaSBx} where:
{aaSB}
Frequency Band
Description
Syntax
Queries
Table 2.1: Model 4115-300 M&C Queries
continued on page 8...
4115-300 Manual, Rev. H
Page 8