2.2  M&C Commands

The following tables summarize the commands and status queries applicable to the 
4115-300 frequency converter. 

*

 PLEASE NOTE:

 The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected.

 

Table 2.0    Model 4115-300  M&C  Commands

 x = 4 to select band 3: in = (950 to 1950 MHz)  

out = (30000 to 31000 MHz)

 

x = 1 to select RS422

x = 0 to unmute output

x = 1 to mute the output

where:

{aaCMx}

 

Set Mute

Range:  +2000 to +8000 

xxxxx = 5 characters

where:

{aaCOxxxxx}

 

Set Int. 10 MHz reference offset

Range: 0 to 31 

xx = 2 characters

where:

{aaCRxx}

 

Set RS485 address

x = 2 to select RS485 

x = 0 to select RS232

where:

{aaC

I

x}

 

Set Serial Interface

Range: 000 to 300 (00.0 to 30.0 in 0.5 dB steps)

xxx = 3 characters

where:

{aaCGxxx}

 Set Gain

x = 3 to select band 3: in = (950 to 1950 MHz)  
out = (29.0 to 30.0 MHz)

x = 2 to select band 2: in = (950 to 1950 MHz)  
out = (28.0 to 29.0 MHz)

x = 1 to select band 1: in = (950 to 1950 MHz)  
out = (27.5 to 28.5 MHz) 

 where:

{aaCBx}

 Set Frequency Band

 Description

 Syntax

   Command

 

 

Table 2.0:   Model 4115-300 M&C Commands

                                                                                                           

4115-300 Manual, Rev. H

 

                      Page 7   

                                 11/16/15

Содержание 4115-300

Страница 1: ...ed without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model number equipmen...

Страница 2: ...tive materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option...

Страница 3: ...tenna hut OR mounted outdoors on an antenna assembly at their specified temperature ranges They are designed to be located out in the elements water sleet snow etc but they are not designed to be subm...

Страница 4: ...MHz Level In Mon Band Specific LO Frequency 30 3 dB 30 to 0 dB variable in 0 5 dB Steps Gain Fc 105 95 80 75 65 1MHz 100kHz 10kHz 1kHz 100 MHz dBC Hz Phase Noise F Hz Controls Indicators Green LED Po...

Страница 5: ...MS3112E14 18S Mating Cable Connector MS3116F14 18P Ethernet Conector RJF21B Mating Cable Connector RJF6G Cable interface Standard RJ45 AC Input Connector Clipper Series CL1M1102 Mating Cable Connector...

Страница 6: ...d CL101021 Backshell Pin Input Connector Pin Description 1 100 240 10 VAC 47 63 Hz 20 watts max 2 Neutral 3 Ground 2 1 Message Protocol The serial format for the RS232 RS422 RS485 port is 9600 baud 8...

Страница 7: ...ge 2000 to 8000 xxxxx 5 characters where aaCOxxxxx Set Int 10 MHz reference offset Range 0 to 31 xx 2 characters where aaCRxx Set RS485 address x 2 to select RS485 x 0 to select RS232 where aaCIx Set...

Страница 8: ...s selected Returns aaSIx where aaSI Serial Interface x 2 if External 10 MHz reference is selected x 1 if Internal 10 MHz reference is selected Returns aaSEx where aaSE 10 MHz reference Range 0 to 300...

Страница 9: ...to 99 degrees Celsius xxx 3 characters Returns aaSTxxx where aaST Internal Temperature y 0 if unit is using internal 10 MHz ref y 1 if unit is using external reference x 0 if no summary alarm x 1 if s...

Страница 10: ...115 300 Ethernet port to the LAN using a normal RJ 45 cable Use any PC on the LAN to connect to the 4115 300 2 4 2 Ethernet Configuration Each 4115 300 must be configured with an appropriate IP addres...

Страница 11: ...delimiter dots example 192 168 192 47 Click on apply settings to apply the new settings in the device server 2 4 3 Web page M C Enter the following address in a web browser to access the M C web page...

Страница 12: ...ws XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock from the Con...

Страница 13: ...SNMP community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of...

Страница 14: ...Figure 2 F Device Server Configuration Menu 4115 300 Manual Rev H Page 14 11 16 15...

Страница 15: ...S CONTROL CONNECTOR Weatherized MS3112E14 18S 18 pin connector See Table 2 6 REF INPUT Type N female 50 0 95 to 1 95 dBm See Table 2 1 ETHERNET CONNECTOR Weatherized Standard RJ45 Ethernet Connector F...

Страница 16: ...tor and Control Connector Monito Monitor and Control Connector Pinout MS3112E14 18S Conne Connector part number MS3112E14 18S Mating Mating Connector part number MS3116F14 18P Pin Signal Description A...

Страница 17: ...J2 or EXT for external 10 MHz 2 to 8 dBm ref that is inserted at J2 on front panel switch S1 see Table 2 0 8 Check that a 10 MHz signal is present at the 10 MHz REF OUTPUT at the same level as the inp...

Страница 18: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 4115 300 Manual Rev H...

Отзывы: