2.2 M&C Commands
The following tables summarize the commands and status queries applicable to the
4115-300 frequency converter.
*
PLEASE NOTE:
The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected.
Table 2.0 Model 4115-300 M&C Commands
x = 4 to select band 3: in = (950 to 1950 MHz)
out = (30000 to 31000 MHz)
x = 1 to select RS422
x = 0 to unmute output
x = 1 to mute the output
where:
{aaCMx}
Set Mute
Range: +2000 to +8000
xxxxx = 5 characters
where:
{aaCOxxxxx}
Set Int. 10 MHz reference offset
Range: 0 to 31
xx = 2 characters
where:
{aaCRxx}
Set RS485 address
x = 2 to select RS485
x = 0 to select RS232
where:
{aaC
I
x}
Set Serial Interface
Range: 000 to 300 (00.0 to 30.0 in 0.5 dB steps)
xxx = 3 characters
where:
{aaCGxxx}
Set Gain
x = 3 to select band 3: in = (950 to 1950 MHz)
out = (29.0 to 30.0 MHz)
x = 2 to select band 2: in = (950 to 1950 MHz)
out = (28.0 to 29.0 MHz)
x = 1 to select band 1: in = (950 to 1950 MHz)
out = (27.5 to 28.5 MHz)
where:
{aaCBx}
Set Frequency Band
Description
Syntax
Command
Table 2.0: Model 4115-300 M&C Commands
4115-300 Manual, Rev. H
Page 7
11/16/15