1.3 Monitor & Control Interface
The following tables summarize the commands and status queries applicable to the
3116-T71-184 Multi-Band Translator
.
*
PLEASE NOTE:
The two character {aa} prefix, shown in the table below, is present ONLY when RS485 is selected.
Table
2.0
Model 3116-T71-184 M&C Commands
-2000
≤
xxxxx
≤
+2000
where:
{aaCOxxxxx}
Set Reference Offset
x = 3 for auto-select
x = 2 to select external reference
x = 6 to select band 6: in = (17.3 to 18.4 GHz)
Out = (10.7 to 11.8 GHz)
x = 5 to select band 5: in = (13.75 to 14.85 GHz)
Out = (11.7 to 12.8 GHz)
x = 1 to select internal reference
where:
{aaCEx}
Set External Reference
x = 0 to unmute the output
x = 1 to mute the output
where:
{aaCMx}
Set Mute
Range: +20 to -40 dB variable in 1±1 dB steps
xxx = 3 characters
where:
{aaCGxxx}
Set Gain
{aaCBx}
Set Frequency Band
x = 1 to select band 1: in = (5.85 to 6.725 GHz)
out = (3.4 to 4.275 GHz)
x = 7 to select band 7: in = (17.3 to 18.4 GHz)
Out = (11.7 to 12.8 GHz)
x = 4 to select band 4: in = (13.75 to 14.85 GHz)
out = (10.7 to 11.8 GHz)
x = 3 to select band 3: in = (12.75 to 13.25 GHz)
out = (11.7 to 12.2 GHz)
x = 2 to select band 2: in = (12.75 to 13.75 GHz)
out = (10.7 to 11.7 GHz)
Description
Syntax
Command
Table 2.0: Model 3116-T71-184 M&C Commands
continued on page 7...
3116-T71-184 Manual, Rev. B
Page 6
05/16/16