3.0 ETHERNET Interface Installation and Operation (Option W8, W18, W29 only)
The 2282-122-21 Block Downconverter is equipped with a 10/100 Base-T compatible Ethernet interface for
control and monitoring of its operating parameters. An HTML script interface allows the user to monitor and
control the converter using a standard web browser. SNMP (Simple Network Management Protocol) is also
supported. Contact Cross Technologies for the SNMP MIB file.
3.1 Methods of Connection
Directly Connected to a PC:
For control from a local PC, attach the 2282-122-21’s Ethernet port to the Ethernet network connector on the
PC using a crossover RJ-45 cable.
LAN Connection
For LAN connections, attach the 2282-122-21 Ethernet port to the LAN using a normal RJ-45 cable.
Use any PC on the LAN to connect to the 2282-122-21.
3.2 Ethernet Configuration
Each 2282-122-21 must be configured with an appropriate IP address, Netmask, and Gateway assigned by your
network manager. The 2282-122-21 is set at the factory with the following network settings:
Factory Network Settings
IP Address:
192.168.123.2
Subnet Mask
255.255.255.000
Gateway
000.000.000.000
The network settings may be changed via the front panel or from the web browser interface.
2282-122-21 Manual, Rev. A