Commands continued on page 11...
TABLE 1.3 2282-122-2
21
2282-122-
21 Commandds
TABLE 1.3 2282-122-21 Commands continued...
Command
Syntax * Description
Set Priority
{aaCPx}
where:
aa = unit address, range = 00 to 31,only used if interface is RS485,
otherwise omit.
P = command code
This command sets the auto switching priority to either 1 or 2,
where x=1 or 2 respectively.
example: {CP2}
Will set the switch to prioritize channel 2 if both are alarmed.
The unit will reply with the '>' character if the command is
sucessfully processed.
Switch Reset
{aaCB}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485,
otherwise omit
B = command code
This command has the same effect as pressing the front panel
Switch Reset button.
example: {CB}
Will return a unit to Auto mode if it is in Remote mode.
Also, this command will reset the switch position if it is currently
"latched" to CH2 in the Latch to CH2 mode (and if CH1 is not alarmed).
The unit will reply with the '>' character if the command is
sucessfully processed.
Set Nominal Current
{aaCNx}
where:
aa = unit address, range = 00 to 31, only used if interface is RS485,
otherwise omit
N = command code
x = desired amplifier channel to set
This command will set channel x nominal current value to the
actual value that is presently being measured.
example: {CN2}
Will measure the current drawn from channel 2's amplifier and set
the nominal value to the measured value.
The unit will reply with the '>' character if the command is
sucessfully processed.
2282-122-21 Manual, Rev. A
Page 10
07/01/20