2.5 Menu Settings
2.5.1 Functions
This section describes operation of the front panel controls. There are three operator switches, the
LCD display and alarm indicator LEDs. All functions for the equipment are controlled by these components.
The functions are (see Figure 2.4):
Power Up
Normal Display
Menu 1 Enable Manual mode
Menu 1a Manually Set Switch Position
Menu 2 Set Channel 1 Attenuation
Menu 3 Set Channel 2 Attenuation
Menu 4 Set Channel 3 Attenuation
Menu 5 Set AMP1 Current Window? Y/N
If Y then --> Menu 5a Set Nominal current to Actual Measured value of AMP1 current? Y/N
Menu 6 Set AMP2 Window? Y/N
If Y then --> Menu 6a Set Nominal current to Actual Measured value of AMP2 current? Y/N
Menu 7 Set AMP3 Window? Y/N
If Y then --> Menu 7a Set Nominal current to Actual Measured value of AMP3 current? Y/N
Menu 8 Set Priority
Menu 9 Set Serial Interface
Menu 10 Set RS485 Remote Address
Menu 11 Display Internal PCB Temperature
Menu 12 Change Network Settings (Ethernet option)
If Y then --> Menu 12a Set IP Address
Menu 12b Set Subnet Mask
Menu 12c Set Gateway Address
Menu 12d Restore Factory Network Settings
Menu 13 Save Settings
Save Menu When “R” is selected or when get to the end.
Alarm indications appear on the LEDs (See figure 2.2).
All program changes must start with the operation of the Menu/Execute switch and must also end with the
operation of the Menu/Execute switch verified by the “Save Settings?” Menu. If this sequence is not followed,
none of the changes will take effect. If programming is initiated and no operator action takes place for
approximately 30 seconds (before the final press of the Menu/Execute switch) the display will revert to its
previous status and you will need to start over.