Section 4. Control From the Console
4.8. «Link remote login» Command
The «Link remote login» command allows connecting to the remote device menu. An
example of the remote menu is given below. To disable the remote menu, press ^X (Ctrl-
X).
Remote login...
(Press ^X to exit)
Cronyx E1-L /ETV-SNMP revision F, 13/04/2005
Mode: Normal, Sensor=Open
Link: Framed, Sync=Int, High gain, HDB3, Use16, CRC4=Gen, Mon=Sa4
Port: 1984 kbps, 100Base-T, Full Duplex
1 3 5 7 9 1 3 5 7 9 1 3 5 7 9 1
Port timeslots: ###############################
1. Statistics
2. Event counters
4. Test...
5. Configure...
0. Reset
Remote (^X to exit): _
In the remote login mode it is possible to monitor the device operating modes, channels
state and view values of error statistics counters. The configuring of the device operation
parameters is also available.
4.9. «Reset» Command
The «Reset» command causes the modem to reset. The device modes stored in the non-
volatile memory (NVRAM) will be in effect after reset.