Modem-Converter E1-L/S
© 2006 Cronyx
Link Testing: Two Ber Testers Enabled Against Each Other
When there is a need to test the E1 link separately in opposite directions, BERTs at both
ends of the link may be enabled simultaneously:
Local device
BER tester is enabled. Indicator TST
lights green in case of no errors
detected and red on errors
E1 link
Remote device
BER
tester
BER
tester
BER tester is enabled. Indicator TST
lights green in case of no errors
detected and red on errors