Crestron
TPMC-10
Isys
i/O
™
WiFi Touchpanel
VT Pro-e Objects and Signal Type Descriptions (continued)
VT Pro-e
OBJECT
VT Pro-e JOIN
DESCRIPTION
(SIGNAL TYPE)
DESCRIPTION
Analog Scrolling
Text Join (Analog
input)
Selects the top line of text to be displayed.
Valid analog values depend on the Scrolling Offset selected in
VT Pro-e, beginning at 0d. The Scrolling Offset determines
the top-most entry (first line) to be displayed and scrolled.
For instance, if there are ten lines of text and Scrolling Offset
is at three, then the fourth line will be seen when the signal is
initialized to 0d, and the first three lines will never be visible.
Separate from the above, VT Pro-e also provides a "Scrolling
Limit Enabled" selection.
For Scrolling Limit Enabled, regardless of the analog value
sent, it will only function between valid ranges.
If there are nine items in the list, and the object shows two
items at a time, setting the analog value to 7d will display the
8th and 9th lines. Sending any other value higher then 7d will
yield no change in the display.
If Scrolling Limit Enabled is not selected, then higher values
for the analog will change the display.
Here, if there are nine items in the list, and the object shows
two items at a time, setting the analog value to 7d will display
the 8th and 9th lines. Sending higher values will show
additional lines, even if there is no text. Thus, a value of 8d
would display the 9th line and a blank line under it. A value of
9d would display two blank lines.
Button
(continued)
Indirect Text Join
(Serial input)
Sends text to the button's text field for display during run time.
Digital Feedback
Join (Digital
input)
Causes the legend to display in the active state for as long as
the input is high.
High/1 (level sensitive) = Active feedback;
Low/0 = Inactive feedback
Analog State Join
and Mode (Active
and Inactive) -
(Analog input)
Selects the mode (appearance) of the legend, in both the
active and inactive states—refer to description for Button.
Analog Scrolling
Text Join (Analog
input)
Selects the top line of text to be displayed—refer to
description for Button.
Legend
Indirect Text Join
(Serial input)
Sends text to the object's text field for display during run time.
Analog Scrolling
Text Join (Analog
input)
Selects the top line of text to be displayed—refer to
description for Button.
Text
Indirect Text Join
(Serial input)
Sends text to the object's text field for display during run time
(continued on next page)