Wall Mount 2-Way RF Compact Color Touchpanel Crestron
STX-1550CW
12
••
Wall Mount 2-Way RF Compact Color Touchpanel: STX-1550CW
Operations Guide - DOC. 5849
Reserve Join Numbers for STX-1550CW Touchpanel
JOIN NUMBER
FUNCTION
VALUE
1015
Power
Off
1016
Stand by
On
1017
Brightness
Low
1018
Brightness
Medium
1019
Brightness
High
1023
Contrast
Up
1024
Contrast
Down
1035
Reboots the Touchpanel
1
N/A
1036
Discharges ST-BTP
N/A
1120 - 1123
Digital Battery
Gauge Bottom (1120) to
Bargraph
Gauge Top (1123)
1160
Keyclick Volume
Up
1161
Keyclick Volume
Down
1172
Keyclick
On
1173
Keyclick
Off
1210
Update Request
N/A
1213
Out of Range (RF) Indicator
N/A
2
1
If finger is left on touchscreen after touchpanel reboots, the touchpanel enters the
SETUP MODE.
2
Only for touchpanel firmware version 5.066.0 or greater.
Problem Solving
Troubleshooting
The table below and continued on the next page provides corrective action for
possible trouble situations. If further assistance is required, please contact a Crestron
customer service representative.
STX-1550CW Touchpanel Troubleshooting
TROUBLE
POSSIBLE
CAUSE(S)
CORRECTIVE ACTION
Touchpanel
does not
function when
docked.
Error caused by
DA-1550CW.
Refer to "Troubleshooting" section of the
latest revision
of the DA-1550CW Operations
& Installation Guide (Doc. 5930).
1
Backlight or power
down timeout has
elapsed.
Touch the screen to reactivate the
touchpanel.
Power is not applied to
the touchpanel.
Verify that power is properly applied and all
connections are made.
Touchpanel
display is too
dark or too
light.
Screen brightness or
contrast is improperly
set.
Hold a finger to the touchscreen for more
than 10 seconds as power is applied. The
display sets the brightness and contrast to a
safe value.
Screens are
wrong.
Screens were not
uploaded.
Upload screens as described in the help files
found in VT Pro-e.
Touchpanel
display is
blank.