CRESTRON
Operations Guide - DOC. 5712
SmartPresenter™: SP-1
••
13
each output. The final step of the procedure is to save the routing settings. Complete
the following procedure to selectively route IR commands to the SP-1 outputs.
1.
Depress (with a blunt object e.g., paper clip) the recessed button
(labeled 1) on the SP-1.
Observe flashing red device output #1 LED.
2.
Depress the recessed button (labeled 2) on the SP-1.
Observe which device output LEDs flash red. A flashing LED
indicates that IR signals intended for the associated outputs are
routed to output #1 on the SP-1. The SP-1 is now in “edit mode”.
3.
Toggle SP-1 recessed button (numbered 2, 3, or 4) to edit routing of IR
commands from a particular output.
Observe that the device output LED associated with the formally
routed output no longer flashes when toggled. Likewise, observe that
the device output LED associated with the device that was not routed
flashes when toggled.
4.
Repeat step 3 as necessary.
5.
Depress the recessed button (labeled 1) on the SP-1 to save routed
settings.
NOTE:
To route the IR signals for all device outputs to OUTPUT 1 on the SP-1,
reapply power to the SP-1 while depressing (with a blunt object e.g., paper clip) the
recessed button (labeled 1) on the SP-1. Release button after LED #1 illuminates
and remains on.
NOTE:
To completely disable routing (i.e., IR signals are only output from their
respective SP-1 output), reapply power to the SP-1 while depressing (with a blunt
object e.g., paper clip) the recessed button (labeled 2) on the SP-1. Release button
after LED #2 illuminates and remains on.
Macro Setup – Linking a Device
The macro capability of the SP-1 allows the “linking” of a controlled function
(assigned to device 4) to the device selection by simply pressing a device button
(1 through 3) on the transmitter.
Device Control Buttons (1 Through 4) on Transmitter