2-Series Card Cage System
Crestron
RACK2
•
Baud rate = 115200 (You can set the PC and the control system to a
different baud rate, by using the
Functions | Set Baud Rate
command).
•
Parity = None.
•
Number of data bits = 8.
•
Number of stop bits = 1.
•
Hardware handshaking (RTS/CTS) enabled.
•
Software handshaking (XON/XOFF) not enabled.
“Port Settings” Window: Default PC Settings for RS-232 Communication with the RACK2.
To verify communication, click
Diagnostics | Establish Communications (Find
Rack)
. This should display a window that gives the COM port and baud rate.
TCP/IP Connection
Before you can communicate with the RACK2 over TCP/IP, you must use the RS-
232 connection just described to configure the unit’s TCP/IP settings. You must also
have one optional Ethernet card (C2ENET-1 or C2ENET-2) installed in Z-Bus slot 1.
1. Open Viewport and click
Functions | Set Control System IP Information.
2. Enter the IP address, IP mask and default router in the text fields. All of
these terms are explained in detail in the Crestron e-Control Reference
Guide (Doc. 6052). The latest version is available as a PDF on the Crestron
website (www.crestron.com).
3. Click
OK
to set the new IP information.
Once you have assigned the IP settings, you can continue to communicate with the
RACK2 using the RS-232 connection, or you can establish a TCP/IP connection.
For TCP/IP, use CAT5 straight through cables with 8-pin RJ45 connectors to
connect the LAN port on the RACK2 and the LAN port on the PC to the Ethernet
hub. Alternatively, you can use a CAT5 crossover cable to connect the two LAN
22
•
2-Series Card Cage System: RACK2
Operations Guide – DOC. 5958