Specifications 

The table below provides a summary of specifications for the TPS-1700.  

Specifications of the TPS-1700 Touchpanel 

SPECIFICATION DETAILS 

Power Requirements 

10 Watts (0.40 Amp @ 24 VDC) 

Default Net ID 

03 

Default Standby Timeout 

10 minutes 

Signal Join Maximums 

4K (digital), 4K (analog), 999 (serial) 

Control System Update Files

 1  

  2-Series Control System 
 CEN/CN-TVAV  
 CNMSX-AV/Pro 
 CNRACKX/-DP 
  CNMS, CNRACK, CNLCOMP 
 ST-CP 

 
Version C2-2004.CUZ or later

2

 

Version 5.13.12V.UPZ or later

3, 4

 

Version 5.12.63X.UPZ or later

3, 4

 

Version 5.10.11W.UPZ or later

3, 4

 

Version 3.18.09m, l, c or later

5

 

Version 4.02.04S.UPZ or later

3

 

Acceptable File Extensions

 

    VT Pro-e 
      .vtp  
      .vtz

 

 
   

Firmware 

      .csf 

 

 
projectname

.vtp (source file) 

projectname

.vtz (compiled file) 

 
 
TPS-1700xxxxxx.csf (panel firmware) 

Memory 

4 MB flash memory (3.5 Mbytes available 

for user programming) 

8 MB SDRAM for firmware storage 

Touchscreen Dimensions 

Height: 3.50 in (8.89 cm) 
Width:  4.60 in (11.68 cm) 
Diagonal: 5.70 in (14.48 cm) 

Touchscreen Resolution 

320 x 240 pixels, 64K colors (16-bit) 

Touchscreen Viewing Angles 

±65° for X dir, +65°/-40° for Y dir 

Touchscreen LCD 

Active matrix 

Touchscreen Illumination 

Backlit fluorescent 

Touchscreen Composition 

Resistive Membrane 

Operating Temperature 

50° to 113°F (10° to 45°C) 

Humidity 

10% to 90% RH (non-condensing) 

Overall Dimensions 

Width:   8.75 in (22.22 cm) 
Height:  3.85 in (9.78 cm) 
Depth:   5.51 in (14.00 cm) 

Weight  

1.85 lb (0.84 kg)  

1. 

The latest versions can be obtained from the Downloads | Software Updates section of the Crestron 
website (

www.crestron.com)

. Refer to NOTE after last footnote. 

2. 

Crestron 2-Series control systems include the AV2 and PRO2. Consult the latest Crestron Product 
Catalog for a complete list of 2-Series control systems. 

3. 

CNX update files are required for either CNMSX-AV/PRO or CNRACKX/-DP. Filenames for CNX 
update files have a UPZ extension and are in one EXE or zipped UPZ file. To avoid program problems, 
make certain you are using the update file with the correct suffix letter (e.g., S, V, W, X). 

4. 

When loading touchpanel projects or firmware through the RS-232 port of the control system, 
Viewport may post the “Transfer Failed” message. To ensure successful data transfer, set the baud rate 
to 38400 (Cresnet speed) or lower. 

5. 

These control systems do not support file transfers (firmware or touchpanel projects) over Cresnet. File 
transfers must be directly uploaded through the RS-232 port. 

6. 

Extension requires a prefix specific to the touchpanel type. In DETAILS, 

projectname

 represents the 

assigned project name, and xxxxxx represents a version number. 

Содержание Isys TPS-1700

Страница 1: ...Crestron TPS 1700 Isys Wired 5 7 Inch Tabletop Touchpanel Operations Guide...

Страница 2: ...by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respectiv...

Страница 3: ...tware Requirements for the PC 10 Programming with Crestron System Builder 11 Programming with SIMPL Windows 11 Programming with VT Pro e 15 Optional Pushbuttons 16 Reserved Join Numbers 16 MultiByte I...

Страница 4: ......

Страница 5: ...el TPS 1700 Introduction Functions and Features The TPS 1700 is a compact Crestron Isys wired 5 7 inch tabletop touchpanel that provides user interface to a Crestron remote control system Cresnet syst...

Страница 6: ...ctive matrix Touchscreen Illumination Backlit fluorescent Touchscreen Composition Resistive Membrane Operating Temperature 50 to 113 F 10 to 45 C Humidity 10 to 90 RH non condensing Overall Dimensions...

Страница 7: ...P only New users may be required to register to obtain access to certain areas of the site including the FTP site Physical Description The touch sensitive viewing screen is located on the front of the...

Страница 8: ...cal Views of TPS 1700 continued Four rubber feet on the underside of the unit are for stability and to prevent slippage on flat surfaces Industry Compliance As of the date of manufacture this unit has...

Страница 9: ...d be used in the following resistance equation to calculate the value on the right side of the equation Resistance Equation R Resistance refer to table below L Length of run or chain in feet PF Power...

Страница 10: ...SETUP MODE the MAIN MENU shown to the left displays four buttons Touch Screen Calibration Exit and Run Program Setup and Diagnostics Selecting Exit and Run Program verifies that all of the setup infor...

Страница 11: ...o set the Cresnet network identity CRESNET ID After the Cresnet ID setting has been verified touch the Return button at the bottom of the screen to save the setting and display the SELECT INTERFACE me...

Страница 12: ...The default is DISABLED Select the Return button to return to the SETUP MENU Power Management Timeout Settings POWER MANAGEMENT TIMEOUT SETTINGS The Power Management Timeout feature is a screen saver...

Страница 13: ...able are supplied to convert a 4 pin Cresnet connection on the control system to the 6 pin connection in the touchpanel The following figure shows the pinout for the 6 pin RJ 11 Recommended Touchpanel...

Страница 14: ...ing using the easiest method Crestron System Builder and use advanced techniques that are available from SIMPL Windows to customize the job VT Pro e is a Windows compatible software package for creati...

Страница 15: ...with SIMPL Windows NOTE The following assumes that the reader has knowledge of SIMPL Windows If not refer to the extensive help information provided with the software NOTE In the following description...

Страница 16: ...d into the upper pane of System Views Additional touchpanels are assigned different Net ID numbers as they are added C2Net Device Slot 9 Setting the Net ID in Device Settings Double click the TPS 1700...

Страница 17: ...inition the signal connected there will be an analog signal In SIMPL Windows the signal types are color coded as follows Digital Blue Analog Red Serial Black Other Green NOTE Other signals are a combi...

Страница 18: ...a to which it points Thus serial signals are used to facilitate the transmission of serial data strings of characters These signals can be generated by incoming data on a COM port or by a symbol that...

Страница 19: ...ional graphics and text A set of pages which make up a project can be designed for each TPS 1700 touchpanel application Each page contains objects such as custom control graphics two and three dimensi...

Страница 20: ...VT Pro e Select a button from the Button drop down list and then select the desired page from the Page Flip drop down list When the button is pressed the page is displayed The quick pushbuttons can a...

Страница 21: ...as more than 256 characters 28 in a font For example Chinese fonts contain several thousand characters Other multibyte languages include Japanese and Korean There are two separate issues with multibyt...

Страница 22: ...velopment tools when uploading programs and projects The following sections define how one would upload a SIMPL Windows program VT Pro e project or upgrade the firmware of the TPS 1700 touchpanel Howe...

Страница 23: ...rt SIMPL Windows or VT Pro e and from the menu bar select Tools Viewport 2 From the Viewport menu select Setup Communications settings alternatively press Alt D to open the Port Settings window Refer...

Страница 24: ...ntrol system Uploading a SIMPL Windows Program A control system source file has the extension smw A compiled SIMPL Windows file has the extension spz for a 2 Series control system bin for CNX generati...

Страница 25: ...not contain any SIMPL modules only the SIMPL Program check box will be enabled If it does contain SIMPL modules then the SIMPL check box will also be enabled Select one or both check boxes and then c...

Страница 26: ...e VT Pro e file vtp and click Open 3 Select File Upload Project Upload via Crestron Viewport 1 Verify that the procedure for Communication Settings that begins on page 18 has been performed 2 As shown...

Страница 27: ...nsion csf To take advantage of all the TPS 1700 touchpanel features it is important that the unit contains the latest firmware available Therefore please check the Crestron website http www crestron c...

Страница 28: ...select File Transfer Update Touchpanel Firmware from the Viewport menu File Transfer Update Touchpanel Firmware Command 3 As shown after this step select the Net ID of the TPS 1700 touchpanel and then...

Страница 29: ...COM port being used to communicate to the control system Transfer speed discrepencies Do the following 1 Lower the baud rate to 38400 to match the Cresnet bus speed 2 Confirm RTS CTS is checked Xon X...

Страница 30: ...headquarters at 1 888 CRESTRON 1 888 273 7876 In Europe call Crestron International at 32 15 50 99 50 In Asia call Crestron Asia at 852 2341 2016 In Latin America call Crestron Latin America at 5255...

Страница 31: ...the front bezel to the base Holding the bezel to the base return the unit to its normal position and lift the bezel from the base 3 Assemble the supplied membrane switches to the pushbutton sets Noti...

Страница 32: ...cluding but not limited to using the Software a either directly or through commands data or instructions from or to another computer b for local campus or wide area network internet or web hosting ser...

Страница 33: ...ubstantially in accordance with the published specifications for a period of ninety 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limite...

Страница 34: ...isplay and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON deal...

Страница 35: ...Crestron TPS 1700 Isys Wired 5 7 Inch Tabletop Touchpanel Operations Guide DOC 6223A Isys Wired 5 7 Inch Tabletop Touchpanel TPS 1700 31 This page intentionally left blank...

Страница 36: ...Crestron Electronics Inc Operations Guide DOC 6223A 15 Volvo Drive Rockleigh NJ 07647 10 04 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice...

Отзывы: