Crestron
TPS-1700
Isys
®
Wired 5.7 Inch Tabletop Touchpanel
Operations Guide - DOC. 6223A
Isys
®
Wired 5.7 Inch Tabletop Touchpanel: TPS-1700
•
17
Digital Reserved Join Numbers TPS-1700
JOIN NUMBER
FUNCTION
VALUE
DIRECTION
*
17216
Brightness
Up
I
17217
Brightness
Down
I
17218
Brightness
High
I
17219
Brightness
Medium (Default)
I
17220
Brightness
Low
I
17230
Standby
On
I/O
17231
Standby Timeout
Up
I
17232
Standby Timeout
Down
I
17242
Setup
N/A
I
17302
Keyclick
On
I/O
17303
Keyclick
Off
I/O
17304
Key Click Volume
Up
I
17305
Key Click Volume
Down
I
17322
Key Click Short
Short (Default)
I
17323
Key Click Medium
Medium
I
17324
Key Click Long
Long
I
*
"I" indicates that pressing a button with this join number commands the touchpanel to perform the
function. "O" indicates feedback to the display (all actions are local to the touchpanel, no
information is transmitted).
MultiByte International Characters
Most languages use a single byte of 8 bits to represent a character, e.g. English,
French, German, Hebrew, Russian, Thai, etc.
Multibyte character fonts require more than the usual 8 bits to specify a character.
This occurs when a language has more than 256 characters (2
8
) in a font. For
example, Chinese fonts contain several thousand characters. Other multibyte
languages include Japanese and Korean.
There are two separate issues with multibyte characters - static text on buttons and
indirect text on buttons. No Isys touchpanel firmware changes are required in either
case.
Static text on a button, entered in the standard way in VTPro-e, always works under
Windows 98. Under Windows XP, you must use VTPro-e 3.0 or later.
Indirect text on a button is entered in VTPro-e and the actual string to be displayed is
entered in SIMPL Windows. You must use VTPro-e 3.0 or later to guarantee that the
full set of characters in the font is stored on the touchpanel. You must use SIMPL
Windows 2.03.11 or later to enter Chinese characters directly. As of this publication
date, only completely single-byte or completely multibyte strings may be entered or
they will not be compiled correctly in SIMPL Windows. In other words, you cannot
enter Chinese character interspersed with numbers. You can enter Chinese characters
or numbers in separate strings. Crestron is scheduling time to fix this in the near
future and the release notes for SIMPL Windows will mention it.
Of course, you can always use the workaround of showing a graphic that displays the
string, but it is not dynamic.
Содержание Isys TPS-1700
Страница 1: ...Crestron TPS 1700 Isys Wired 5 7 Inch Tabletop Touchpanel Operations Guide...
Страница 4: ......