Tiered Switching 

e-Schedule does not currently support tiered switching, i.e., any environment 
that does not offer full crosspoint capability. For the e-Schedule system to 
function properly it must be able to switch any source to any destination 
without interfering with the routes of other sources or destinations or 
requiring allocation of a limited number of intermediate channels. 

System Components and CNX Gateway Licensing 

The e-Schedule software package consists of the following: 

• 

Active Server Pages

—Web server application for scheduling 

and conflict checking. 

• 

Real-Time Engine

—application for controlling media resources 

and signal routing between control systems, source devices and 
destination devices. 

• 

e-Schedule Database Directory

—divided into four categories: 

1) Configuration 2) Web Browser 3) Resource and 4) System. 

• 

Documents/Examples Directory

—various SIMPL Windows 

and VT Pro-e programs that define an extensive sample system. 
Together with the completed configuration databases (also 
included), the programs can be used as models for most projects. 

In addition, the system requires a CNX Gateway (the software gateway, not 
the card gateway) to enable Ethernet communication with 
Crestron equipment. The number of connection licenses depends on the 
configuration of the system. 

Crestron recommends two possible software configurations. The first is to 
have all the software and the CNX Gateway on a single computer. In this 
case, the number of connection licenses will be equal to the total number of 
IP addresses (meaning all browsers and any hardware with unique IP 
addresses), 

plus two

. The two extra licenses enable communication between 

the Web Server and Real-Time Engine applications. For example, in the 
following system:  

• 

One CNMSX-Pro controlling various sources 

• 

Five CEN-TVAVs  

• 

Five Web browsers 

A total of thirteen licenses would be required. 

The second possible configuration is to have two computers, one for the Web 
Server and the other for the Real-Time Engine, each with its own CNX 
Gateway. (The Database Directory should be installed on the Web Server for 
efficiency.) The Web Server computer would then require licenses for all 

Programmer’s Guide 

e-Schedule – DOC. 5919  

  3 

Содержание e-Schedule

Страница 1: ...Crestron e Schedule Programmer s Guide Programmer s Guide Crestron e Schedule Crestron Electronics Inc...

Страница 2: ...Source Devices 12 Destination Devices 17 Signals 19 Signal Macros 21 Signal Macros 22 Privileges 23 Join Number Pass Throughs 24 Real Time Engine Scheduler exe 25 Diagnostic Utilities 29 Watch Signal...

Страница 3: ...ong as there is full crosspoint capability Multiple room scheduling and grouping and multiple head ends Global signals Join number pass throughs for direct communication between a Web browser and a ro...

Страница 4: ...dule events which are divided into two types media events and global events To schedule a media event the user requests up to six media titles as well as start and end times and room destinations In a...

Страница 5: ...ams that define an extensive sample system Together with the completed configuration databases also included the programs can be used as models for most projects In addition the system requires a CNX...

Страница 6: ...teway is servicing NOTE Crestron recommends that all e Schedule components reside on a separate segment or subnet of the Ethernet network in order to help ensure that packets will be routed efficientl...

Страница 7: ...ended Crestron Software Files Crestron e Control CNX Gateway 2 8 6 0 or later Active Server Pages Database Directory Real Time Engine PC Hardware 600 MHz Pentium II Processor 128 MB RAM Network Card T...

Страница 8: ...hernet connected destinations 0 1 or more Head Ends SourceN CNMSX Source1 0 1 or more Cresnet connected Misc equip CNMSX Misc equip IR Xmit opt CN TVAV IR Transmitter Touchpanel optional CEN TVAV Brow...

Страница 9: ...grammer s Guide Data Flow Browser Browser Browser Browser Web Server CNX Gateway Real Time Engine CNX Gateway Databases Scheduling information Real time information Crestron Devices Programmer s Guide...

Страница 10: ...ystem as well as real time status of sources and destinations Resource Databases Scheduler_Media mdb media database containing all media resources and media attributes Web Browser Database DO NOT MODI...

Страница 11: ...e Schedule does not currently support multiple Web Servers ServerMachineIPAddress The static IP Address of the Web Server computer Cfg_Hardware_RealTimeMachine Field Name Description RealTimeMachineI...

Страница 12: ...1 and proceeding sequentially gaps are permitted GroupName The name of the group i e First Year Classes referenced by the Group ID and displayed in the user interface Cfg_Area_SubLocations Field Name...

Страница 13: ...1 Example 2 Locations groups and rooms with corresponding tables mapping the relationships between them Group 1 Cfg_Area_MapTable Cfg_Area_Groups Cfg_Area_Locations Cfg_Area_SubLocations Group 3 Room...

Страница 14: ...cher Enable Check box to enable or remove the device in the system Cfg_Source_FormatType Field Name Description FormatTypeId Each format type must be assigned a unique identifier starting with 1 and p...

Страница 15: ...Ignored in baseband systems enter 0 ChannelName The channel name i e Bloomberg History Channel SwitcherInput In baseband systems only this is the switcher input ID number that is specified in SIMPL Wi...

Страница 16: ...ecimal equivalent of the Cresnet IP ID of the device SwitcherID For baseband systems this is the switcher used by the device This ID number is taken from the table Cfg_Hardware_Switcher Ignored in bro...

Страница 17: ...abase Table Cfg_Hardware_Source Database Table Status_Src SrcStatusId 3 SrcStatusDesc Ready Database Table RealTimeSrcStatus SrcId 3 SrcStatus 0 Database Table Cfg_Hardware_Switcher SwitcherId 1 Switc...

Страница 18: ...Crestron e Schedule Programmer s Guide Programmer s Guide e Schedule DOC 5919 16 Example 4 continued...

Страница 19: ...aken from Cfg_Hardware_RealTimeMachine this ID number must be 1 IPAddress The static IPAddress of the set top box or control system if set top box does not have its own IP Address IPID The decimal equ...

Страница 20: ...Field Name Description OptionId ID for the conflict checking option see below OptionName 1 RecurringEvents not available 2 Groups 3 Multilocation Active Check box to enable or disable each option Opt...

Страница 21: ...stat Cfg_EventSignals_Signals Field Name Description EventSignalId Every signal must be assigned a unique identifier starting with 1 and proceeding sequentially gaps are permitted EventSignalName The...

Страница 22: ...erenced by the FolderNameId and displayed in the user interface Cfg_EventSignals_MapTable Field Name Description FolderNameId Taken from Cfg_EventSignals_Folders EventSignalId Taken from Cfg_EventSign...

Страница 23: ...grammer s Guide e Schedule DOC 5919 21 IO 0 Output from the Real Time Engine 1 Real Time Engine will receive this signal from the hardware IOType 1 Digital 2 Analog 3 Serial CNXType 0 None 1 Source 2...

Страница 24: ...nal into the table Cfg_EventSignals_Signals The EventSignalID must be 1000 Then in the table Cfg_EventSignals_MacroMapTable define the signals that this macro will trigger The field Order specifies th...

Страница 25: ...dministrator The recommended default values below assume that the administrator s user ID is 1 Cfg_User_MapTable UserId PrivilegeId _Key 1 1 NONE 1 3 NONE 1 9 NONE 1 10 NONE 1 4 NONE 1 108 NONE 1 5 NO...

Страница 26: ...o its corresponding set top box and those sent from a set top box are transmitted to all connected browsers A pass through is only valid between a Web browser and a set top box not between a Web brows...

Страница 27: ...ne marked Next Scheduled Events to End lists events that are currently in progress while the bottom pane marked Next Scheduled Events to Start lists the events that have been scheduled to start next T...

Страница 28: ...Select Edit Preferences to open the Preferences dialog box which consists of a tabbed page The File Paths tab displays the path that points to the Crestron e Schedule Database Directory containing al...

Страница 29: ...Server See Web Server Gateway IP Address below Web Server Gateway IP Address specifies the IP Address of the CNX Gateway computer for the Web Server Check for scheduled events every n seconds configur...

Страница 30: ...Check for new connections every n seconds since set top boxes and browsers are likely to be dynamically connected and disconnected to the system at any time the Real Time Engine will continuously pol...

Страница 31: ...t from the Scheduler and this is specified in the I O field The IO Type field gives the type of signal digital analog or serial The Value field gives the value that was sent Command Type lists the typ...

Страница 32: ...to view information about the corresponding entries as they appear in the configuration databases The Status window will list any errors or omissions NOTE Whenever a new e Schedule version is install...

Страница 33: ...Crestron e Schedule Programmer s Guide Programmer s Guide e Schedule DOC 5919 31...

Страница 34: ...ple system illustrated in Figure 1 Together with the completed configuration databases also included these can be used as programming models Programming Requirements Firmware Software Version Minimum...

Страница 35: ...IR CNECI 4 ID 7E IR Local VCR Cresnet Local TV Local VCR DVD2 IP ID 0B IR VCR3 IP ID 09 VCR2 IP ID 07 Ethernet IR IR IR Tuner IP ID 0C Touchpanel ID 03 Cresnet Classroom 2 CEN TVAV 192 168 2 171 Clas...

Страница 36: ...1 1 television tuner at IP ID 0C on Headend MSX 1 1 switcher at IP ID 08 on Headend MSX 1 1 CN TVAV Classroom 1 at Cresnet ID 50 which is bridged from Cresnet to Ethernet by Headend MSX 1 2 CEN TVAVs...

Страница 37: ...ropriate control system The Cfg_EventSignals_Signals table can then be configured to schedule and activate specified join numbers on this ActiveCNX Interface Non Ethernet Cresnet Hardware In the sampl...

Страница 38: ...t as usual and the MRHC transmitter will control settings for Power Mute Volume Source Control and View Channel Points to Remember All components of an e Schedule system the Web Server Real Time Engin...

Страница 39: ...indicates to the Scheduler that the specified source device is being requested for use The Scheduler then checks the validity of the request dig i21 i27 Feedback for SourceA SourceF and SourceLocal I...

Страница 40: ...essed dig i41 i42 Mute On and Mute Off Enables the Web browser to control a room s Mute On or Mute Off button dig o43 o44 TV Power On Off Sends feedback to the Web browser when a local TV Power On or...

Страница 41: ...olume Up or Volume Down button dig i63 i64 TV Channel Up Down Enables the Web browser to control a room s TV Channel Up or Channel Down button dig i74 Controlling Room When signal is high indicates th...

Страница 42: ...e Scheduler i e join number 21 which identifies SourceA on the Destination ActiveCNX Interface the Pass Through takes priority and the original command is ignored A signal cannot be configured as both...

Страница 43: ...Controls Can be customized for specified SourceA SourceF transport controls that may not exist in the database i e Super Fast Rewind dig i105 i124 Generic Transport controls Feedback from the customiz...

Страница 44: ...numbers defined in the fixed database Scheduler_RealTimeControl mdb to be used to indicate the unique page on a Crestron touchpanel that would display the transport controls of a device For example if...

Страница 45: ...annel in the Cfg_Hardware_LegalChannels database table Serial Signals i6 i11 Media titles for SourceA SourceF i e The Matrix i12 i17 Device names of SourceA SourceF i e VCR 5 i18 Group name i19 Room n...

Страница 46: ...SS and MN indicates a space Field Description Format HH Hour 00 23 MM Minutes 00 59 SS Seconds 00 59 MN Month 01 12 DD Day 01 31 YYYY Year 4 digits NOTE The Classroom programs of the sample system con...

Страница 47: ...trols Input from the Scheduler to activate a transport control for the corresponding source typically tied to logic for the device or to an IR driver o21 o40 Transport feedback for the source routed f...

Страница 48: ...ontrols that may not exist in the database o41 o60 Generic Transport Controls Feedback for customized transport controls Analog Signals o1 Ready status of the source When initialized to 0 indicates th...

Страница 49: ...hat should be loaded into the source device for the next event based on the scheduling information When an event is over and the end user physically changes the media in a source device the READY butt...

Страница 50: ...ccession to this ActiveCNX Interface This might occur if there were several rooms in a group and one source was selected the switcher would have to switch the input to each room or if more than one ro...

Страница 51: ...ugh commands data or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement...

Страница 52: ...iod of ninety 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron sha...

Страница 53: ...0 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer rega...

Отзывы: