The following four tables can be used to change the labelling of the folders
that are displayed in the e-Schedule user interface during scheduling
requests. The two main folders, Event Start and Event End, cannot be
modified.
Cfg_EventSignals_Folders
Field Name
Description
FolderNameId
Each folder that displays auto-start signals must be
assigned a unique identifier, starting with 1 and
proceeding sequentially—gaps are permitted.
FolderName
The name of the folder, referenced by the FolderNameId
and displayed in the user interface.
Cfg_EventSignals_MapTable
Field Name
Description
FolderNameId Taken
from
Cfg_EventSignals_Folders.
EventSignalId Taken
from
Cfg_EventSignals_Signals.
Cfg_GlobalEvents_Folders
Field Name
Description
FolderNameId
Each folder that displays global signals must be
assigned a unique identifier, starting with 1 and
proceeding sequentially—gaps are permitted.
FolderName
The name of the folder referenced by the
FolderNameId and displayed in the user interface.
Cfg_GlobalEvents_MapTable
Field Name
Description
FolderNameId Taken
from
Cfg_GlobalEvents_Folders.
EventSignalId Taken
from
Cfg_EventSignals_Signals.
Programmer’s Guide
e-Schedule – DOC. 5919
•
20