Crestron
e-Schedule
Programmer’s
Guide
Signal Macros
Signal Macros are now implemented in e-Schedule v3.02. Signal Macros
combine groups of individual signals and eliminate the need for the user to
select each signal separately. Signal Macros can be be used at the beginning
and/or end of a Media Event and in Global Signal Events.
For example, at the beginning of an media event, a user can select a signal,
Auto Start, which will automatically execute the signals, TV Power On,
Select Source A, and Play.
To insert a signal macro, insert a new signal into the table,
Cfg_EventSignals_Signals
. The EventSignalID must be >= 1000. Then in the
table,
Cfg_EventSignals_MacroMapTable
, define the signals that this macro
will trigger. The field, Order, specifies the sequence order in which each
signal will be triggered within the event.
For example, the macro, Auto Start, will trigger signals 250, 300, and 301
(TV Power On, Select Source A, and Play).
Cfg_EventSignals_Signals
EventSignalID
EventSignalName
Join Number
HardwareID
250
TV Power On
…
…
251
TV Power Off
…
…
300
Select Source A
…
…
301 Play … …
302 Stop … …
1000 Auto
Start N/A
N/A
1001 Auto
Stop N/A
N/A
Cfg_EventSignals_MacroMapTable
MacroID
SignalID
Order
1000 250 1
1000 300 2
1000 301 3
1001 251 1
1001 300 2
1001 302 3
Programmer’s Guide
e-Schedule – DOC. 5919
•
22